If  the  device  is  intended  for  outdoor  use,  we  rec-
ommend  permanently  protecting  the  membrane 
keypad  against  UV  radiation  and  using  a  suitable 
enclosure  or  at  least  the  erection  of  a  sufficiently 
dimensioned  canopy  as  a  protection  measure 
against constant rain or snow. 

4.1 

Process connection 

• 

By authorized and qualified specialized person-
nel only. 

• 

The  pipes  need  to  be  depressurized  when  the 
instrument is being connected. 

• 

Appropriate  steps  must  be  taken  to  protect  the 
device from pressure surges. 

• 

Check the suitability of the device for the media 
to be measured. 

• 

Check  that  the  pressure  connections  do  not 
leak before commissioning. 

• 

Maximum pressures shall be observed. 

• 

Do not blow into the pressure connections! 

The  pressure  connections  are  marked  with (+)  and 
(-)  symbols  on  the  device.  For  differential  pressure 
measurements, the higher pressure is connected to 
the (+) side and the lower pressure to the (-) side of 
the device. 

The  pressure  measuring  lines  must  be  installed  on 
a  gradient  so  that  no  air  pockets  e.g.  for  liquid 
measurements,  water  pockets  or  for  gas  measure-
ments  can  be  created.  If  the  required  incline  is  not 
reached, water and/or air filters need to be installed 
at suitable points.  

The pressure sensing lines need to be kept as short 
as  possible  and  installed  without  sharp  bends  to 
avoid interfering delay times. 

If the pressure sensing lines are already 
pressurised  at  the  time  of  commission-
ing,  zero-point  control  and  adjustment 
cannot be performed. In such cases, the 

device should be only connected to the mains with-
out the pressure sensing lines. 

4.2 

Electronic connection 

• 

By authorized and qualified specialized person-
nel only. 

• 

The electrical connection of the device shall be 
performed according to relevant VDE  and  local 
electricity board regulations. 

• 

Disconnect  the  system  from  the  mains  before 
connecting the device. 

• 

Add a fuse adapted to the energy requirements. 

 

 

 

Connector 1: Power supply and output signal 

 

 

Connector 2 : Switching outputs 

 

The  nominal  supply  voltage  and  the  permissible 
range can be found in the technical data. 

The  admissible  load  /  resistance  for  the  signal  out-
put is stated in the technical data. 

The  connection  "Signal  ground

“(-Sig)  is  connected 

internally to the supply ground. It only serves as the 
ground connection for the output signal. This means 
that  the  output  signal  is  free  of  interference  levels 
on the power supply lines. 

BN

 

WH

 

BU

 

BK

 

bridged internally 

S

ign

a

-S

ig

 

P

o

w

e

s

u

p

p

ly

 -

U

b

 

S

ign

a

+

S

ig

 

n

.c

P

o

w

e

s

u

p

p

ly

 

+U

b

 

BN

 

WH

 

BU

 

BK

 

SP1

 

SP2

 

SP2

 

SP1

 

Summary of Contents for DE44

Page 1: ...zed personnel familiar with the in stallation commissioning and operation of this product Specialized personnel are persons who can assess the work they have been assigned and recognize potential dang...

Page 2: ...eed between the manufacturer and user 3 Description of the product and func tional description 3 1 Function diagram 3 2 Design and mode of operation The device is based on two piezo resistive sensor e...

Page 3: ...ilters need to be installed at suitable points The pressure sensing lines need to be kept as short as possible and installed without sharp bends to avoid interfering delay times If the pressure sensin...

Page 4: ...tions step by step Depending on the device model 1 some menu items may not be available For example all characteristic curve functions are faded out in the menu if the de vice does not have a signal o...

Page 5: ...isplay output signal and switch points but not on the measuring cell it self This parameter can be used to set the reaction time to the pressure jumps The value range is 0 0 s to 100 0 s But with maxi...

Page 6: ...means of hydrostatic pressure measure ments are two typical examples of this In these cases you might want to change the output signal of the transmitter to a non linear characteristic curve so that t...

Page 7: ...ue 000 cancels the password function If a password has been issued the text PAS appears after ESc and and you need to enter the correct value using and You will only arrive at all other menu items aft...

Page 8: ...e of the de vice can be shown sensibly MA Start of measuring range The measuring value is set in that the output signal is minimal e g 0V 0mA or 4mA ME End of measuring range The measuring value is se...

Page 9: ...must not be exposed to mechanical shocks It shall be transported only in packaging specifically intended for transport 8 Service All damaged or faulty devices shall be directly sent to our repair depa...

Page 10: ...4 20 mA 0 10 V DC Admissible apparent ohmic resistance RL Ub 4 V 0 02 A Ub 26V RL 1100 Ub 26V RL 2 K Ub 15V RL 10 K Ub 12 15V Characteristic curve can be programmed Power consumption approx 2 W VA Di...

Page 11: ...ith 3 30 support points Password 001 999 000 no password protection Comments 0 For values from 0 2 the display switches between dP1 and dP2 rhythmically 1 Measuring values around zero are set to zero...

Page 12: ...5 6 0 40 mbar 5 7 0 60 mbar 5 8 0 100 mbar 5 9 2 5 2 5 mbar A 6 4 4 mbar A 7 6 6 mbar A 8 10 10 mbar A 9 16 16 mbar B 1 25 25 mbar B 2 40 40 mbar C 5 60 60 mbar B 3 100 100 mbar B 4 0 400 Pa D 7 0 60...

Page 13: ...40 mbar 5 7 0 60 mbar 5 8 0 100 mbar 5 9 2 5 2 5 mbar A 6 4 4 mbar A 7 6 6 mbar A 8 10 10 mbar A 9 16 16 mbar B 1 25 25 mbar B 2 40 40 mbar C 5 60 60 mbar B 3 100 100 mbar B 4 0 400 Pa D 7 0 600 Pa D...

Page 14: ...sured value display contact elements 3 1 2 digit LED 2 relay contacts 3 3 1 2 digit LED 2 semiconductor switches 6 Electrical connection M12 plug connection M Assembly option Standard attachment boreh...

Page 15: ...14 Declaration of Conformity...

Page 16: ...ject to change without notice Changements techniques sous r serve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesst...

Reviews: