Table of Content 

1

 

Safety guidelines

 

2

 

Intended use

 

3

 

Description of the product and functional description

 

4

 

Installation and assembly

 

5

 

Commissioning

 

6

 

Maintenance

 

7

 

Transport

 

8

 

Service

 

9

 

Accessories

 

10

 

Disposal

 

11

 

Technical data

 

12

 

Dimensional drawings

 

13

 

Order Codes

 

14

 

Declaration of Conformity

 

 

 

Safety guidelines 

1.1 

General Information 

This  operating  manual  contains  instruc-
tions  fundamental  to  the  installation, 
operation  and  maintenance  of  the  in-
strument  that  must  be  observed  uncon-

ditionally. It must be read by the assembler, opera-
tor  and  the  specialized  personnel  in  charge  of  the 
device before it is installed and put into operation.  

This  operating  manual  is  part  of  the  product  and 
therefore  must  be  kept  close  to  the  device  in  a 
place  that  is  easily  accessible  for  the  responsible 
personnel. 

The following sections, in particular the instructions 
about  assembly,  commissioning  and  maintenance, 
contain 

important 

safety 

information, 

non-

observance  of  which  could  lead  to  risks  to  people, 
animals, the environment and objects. 

1.2 

Personnel Qualification 

The  instrument  may  only  be  installed  and  commis-
sioned by specialized personnel familiar with the in-
stallation,  commissioning  and  operation  of  this 
product. 

Specialized personnel are persons who can assess 
the  work  they  have  been  assigned  and  recognize 
potential dangers by virtue of their specialized train-
ing, their skills and experience and their knowledge 
of the pertinent standards. 

1.3 

Risks due to Non-Observance of  
Safety Instructions 

Non-observance of these safety instructions, the in-
tended use of the device or the limit values given in 
the  technical  specifications  can  be  hazardous  or 
cause  harm  to  persons,  the  environment  or  the 
plant itself.  

Claims for damages from the manufacturer are ex-
cluded in this case. 

1.4 

Safety Instructions for the Operating 
Company and the Operator 

The  safety  instructions  on  correct  operation  of  the 
device  shall  be  observed.  The  operating  company 
must  make  them  available  to  the  installation, 
maintenance, inspection and operating personnel.  

Dangers arising from electrical components, energy 
discharged  by  the  medium,  escaping  medium  and 
incorrect installation of the instrument must be elim-
inated.  For  more  information,  please  refer  to  the 
applicable national and international regulations. 

In Germany these are the DIN EN, UVV and, in in-
dustry-specific  cases,  the  DVGW-,  Ex-,  GL-,  etc., 
the VDE guidelines and the regulations of the local 
power utility companies. 

 

Operating Manual 

 

DE44 

Digital two-channel  

 

Differential pressure switch / Transmitter 

 

 

 

Summary of Contents for DE44

Page 1: ...zed personnel familiar with the in stallation commissioning and operation of this product Specialized personnel are persons who can assess the work they have been assigned and recognize potential dang...

Page 2: ...eed between the manufacturer and user 3 Description of the product and func tional description 3 1 Function diagram 3 2 Design and mode of operation The device is based on two piezo resistive sensor e...

Page 3: ...ilters need to be installed at suitable points The pressure sensing lines need to be kept as short as possible and installed without sharp bends to avoid interfering delay times If the pressure sensin...

Page 4: ...tions step by step Depending on the device model 1 some menu items may not be available For example all characteristic curve functions are faded out in the menu if the de vice does not have a signal o...

Page 5: ...isplay output signal and switch points but not on the measuring cell it self This parameter can be used to set the reaction time to the pressure jumps The value range is 0 0 s to 100 0 s But with maxi...

Page 6: ...means of hydrostatic pressure measure ments are two typical examples of this In these cases you might want to change the output signal of the transmitter to a non linear characteristic curve so that t...

Page 7: ...ue 000 cancels the password function If a password has been issued the text PAS appears after ESc and and you need to enter the correct value using and You will only arrive at all other menu items aft...

Page 8: ...e of the de vice can be shown sensibly MA Start of measuring range The measuring value is set in that the output signal is minimal e g 0V 0mA or 4mA ME End of measuring range The measuring value is se...

Page 9: ...must not be exposed to mechanical shocks It shall be transported only in packaging specifically intended for transport 8 Service All damaged or faulty devices shall be directly sent to our repair depa...

Page 10: ...4 20 mA 0 10 V DC Admissible apparent ohmic resistance RL Ub 4 V 0 02 A Ub 26V RL 1100 Ub 26V RL 2 K Ub 15V RL 10 K Ub 12 15V Characteristic curve can be programmed Power consumption approx 2 W VA Di...

Page 11: ...ith 3 30 support points Password 001 999 000 no password protection Comments 0 For values from 0 2 the display switches between dP1 and dP2 rhythmically 1 Measuring values around zero are set to zero...

Page 12: ...5 6 0 40 mbar 5 7 0 60 mbar 5 8 0 100 mbar 5 9 2 5 2 5 mbar A 6 4 4 mbar A 7 6 6 mbar A 8 10 10 mbar A 9 16 16 mbar B 1 25 25 mbar B 2 40 40 mbar C 5 60 60 mbar B 3 100 100 mbar B 4 0 400 Pa D 7 0 60...

Page 13: ...40 mbar 5 7 0 60 mbar 5 8 0 100 mbar 5 9 2 5 2 5 mbar A 6 4 4 mbar A 7 6 6 mbar A 8 10 10 mbar A 9 16 16 mbar B 1 25 25 mbar B 2 40 40 mbar C 5 60 60 mbar B 3 100 100 mbar B 4 0 400 Pa D 7 0 600 Pa D...

Page 14: ...sured value display contact elements 3 1 2 digit LED 2 relay contacts 3 3 1 2 digit LED 2 semiconductor switches 6 Electrical connection M12 plug connection M Assembly option Standard attachment boreh...

Page 15: ...14 Declaration of Conformity...

Page 16: ...ject to change without notice Changements techniques sous r serve Fischer Mess und Regeltechnik GmbH Bielefelder Str 37a D 32107 Bad Salzuflen Tel 49 5222 9740 Fax 49 5222 7170 eMail info fischermesst...

Reviews: