Installation
30.10.12
Chapter 11: Installation - Page 147
Please note!
Due to the terminals being exposed, the protection class IP 04
applies to the iControl2 panel.
If properly installed with a seal (e.g. Sikaflex), up to IP66 can be
achieved.
11.4 Wiring of the Panda iControl2 controller
Fig. 11.4-1: Wiring of the Panda iControl2 controller
The Panda iControl2 controller is connected to the wire harness with the 18-pin jack. The centre 6-pin jack is
designed for the Fischer Panda standard bus. The Panda iControl2 panel is connected to this jack. The Fischer
Panda CAN bus is connected to the 6-pin jack at the bottom right of the circuit board. The configuration of the
connectors is given in the subsequent tables. See “Terminal assignments on the Panda iControl2 controller” on
Page 148.
1. Connecting jack for wire harness, 18-pin
2. Connecting jack, 6-pin, Fischer Panda standard bus
3. Connecting jack, 6-pin, Fischer Panda CAN bus for optional use
4. Connecting bolt for phase L3 (load output to inverter) and input from winding L3
5. Connecting bolt for phase L2 (load output to inverter) and input from winding L2
6. Connecting bolt for winding L1
7. Connecting bolt for phase L1 (load output to inverter)
8. Input for supply v12V
9. Pre-heating output
Summary of Contents for 5000i PVK-U
Page 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 30 10 12 Leere Seite Intentionally blank Basics...
Page 48: ...The Panda Generator Seite Page 48 Kaptitel Chapter 4 The Panda Generator 30 10 12...
Page 126: ...Generator Tables Seite Page 126 Kaptitel Chapter 8 Generator Tables 30 10 12...
Page 150: ...Page 150 Chapter 11 Installation 30 10 12 Intentionally left blank Installation...
Page 152: ...Page 152 Chapter 12 Maintenance 30 10 12 Intentionally left blank Maintenance...
Page 158: ...Page 158 Chapter 14 Annex 30 10 12 Intentionally left blank Annex...