![Fischer Panda 15 mini PMS Digital Manual Download Page 41](http://html1.mh-extra.com/html/fischer-panda/15-mini-pms-digital/15-mini-pms-digital_manual_2294276041.webp)
The Panda Generator
12.8.20
Kapitel/Chapter 4: The Panda Generator - Seite/Page 41
4.3.3 Sensors and switches for operating surveillance
Fig. 4.3.3-1: Thermo-switch at cylinder head
Thermo-sensor at cylinder head
The thermo-sensor at the cylinder head serves the
monitoring of the generator temperature.
Fig. 4.3.3-2: Coil thermo-switch
Thermo-switch in the generator coil
1. Generator coil
2. Thermo-switch 4x165/175°C
3. Housing
For the protection of the generator coil there are two thermo-
switches inside the coil, which are for inserted parallel and
safety's sake independently from each other.
Fig. 4.3.3-3: Thermo-switch at front plate
Thermo-switch at the front plate
The generator bearing is equipped with an thermoswitch,
which switches the engine off if the temperature becomes to
high.
130°C
1
3
2