Generator control system
Based on VCS183
DS_VCS183
Page 35
Rev. 06
www.fischerpanda.com
©Fischer Panda generators Inc.
8.
Fuel pump current
9.
ADC reading from tank sensor
10.
Current output to ground breaker relay
11.
ADC reading on water leak sensor
12.
Operating time since last engine start
13.
Total electric energy produced since last engine start
14.
HEX coded format of shutdow
n only messages (2 lines, “STWL” and “STWH”)
15.
HEX coded format of warning only messages (2 lines, “MSGWL” and “MSGWH”)
16.
HEX coded format of messages only (2 lines, “MISWL” and “MISWH”)
17.
Calendar date as set in this panel
18.
Time as set in this panel
19.
Fischer Panda CAN node address
20.
NMEA node address
View system ID
This menu is made to give access to exact hardware versions, software
versions and serial numbers of devices (CT186 and VCS183) attached
to the control panel via serial data link. Corresponding panel data may
be retrieved from initial panel display right after power up. The panel
will return on its own to basic display menu 1 after 5 seconds. See
Reset to default
Table 8: Programing parameters:
twice in VCS183 memory. One set is the actual one used for control
and monitoring and may be altered by the user. The other one is the
factory default data set for this generator. Performing
a “
Reset to
default
”
will overwrite actual data set with factory settings, thus
placing the control system in the status it was delivered. Cumulative
data, serial numbers, software and hardware version numbers and the
message to be displayed in case of an active fire boy are not affected
by reset to default. Upon such reset to default the control system will
perform a power cycle without user intervention and return to basic
display mode page 1. See
Figure 19: Resetting control system to
Display settings
This menu gives access to basic display settings. Actual settings may be altered using S4, item to be
altered is selected by moving the selection bar using S3. See
•
Units: may be selected metric (temperatures in °C, oil pressure in bar) or imperial (temperatures
in °F, oil pressure in psi)
•
Contrast: Relative number for very light panel (1) to very dark panel (10)
•
Backlight: Relative number for very dim backlight (1) to very bright backlight (10)
•
Panel beeper: May be enabled or disabled. Affects this panel only, other panels on the same
data bus are not affected.
•
Return to normal: Will jump back to basic display mode page 1
Figure 18: View System ID
Figure 19: Resetting control system to
default
Figure 20: Display settings