Installation Instructions
10.6.16
Kapitel/Chapter 5: Installation Instructions - Seite/Page 57
5.9.3.1 Installation location for radiators for roof, side, or underfloor mounting on the
vehicle
Fig. 5.9.3-1: Radiator installation - example
Fig. 5.9.3.1-2: Radiator dimensions
5.9.3.2 Roof installation
Please note:
• Minimum distance to vehicle roof: 100 mm.
• Minimum distance to next vertical wall: 1/2 radiator width.
• Min. distance to gas exhaust (heat and dirt source): 500 mm.
• The max. permissible vehicle height must not be exceeded.
• Install warnings stating new vehicle height inside driver's cab.
• During operation, the exhaust flow must be uninhibited for at least 3 meters.
2
1
3
4
1. Radiator mounted on the roof
2. Radiator mounted in vertical position
3. Radiator build into the vehicle wall
4. Radiator mounted under the vehicle