User notice Primaprotect
version 1.0
7
3.2 Limits
regarding
the
positioning of the posts
Warning
A wrong installation may cause dysfunctions of the system which represents a real danger
to the safety of your child.
Do not expose the posts too close to a reflecting surface (minimum 1.5m). Whichever
season it is do not let any vegetation cut through the infrared beams.
While using the safety bracelet, the maximum distance between the master post and the
furthest possible location of fall of your pool, cannot exceed 30m. The range of the alarm
system depends on the pool environment.
For an optimum efficiency, there should be no obstacle in between the master post and
the edges of the pool (Wall, tree, etc).
The posts must be fixed on a flat ground preferably in concrete with a flatness of more or
less 1 cm. Avoid the following configurations :
Figure 7 : Configurations to avoid
Figure 8a : Vertical positioning
Figure 8b : Horizontal positioning
The slope of the ground can not exceed 10°.
The posts must be positioned, one according to the others, with a minimum angle of 60°
and inferior to 120°.
<10°
120° max
60° min