)$& ,QVWDOODWLRQ DQG 6HWXS *XLGH
7R PRXQW DQG ZLUH WKH 3DQHO /LQN 0RGXOH UHIHU WR
)LJXUH DQG SHUIRUP WKH IROORZLQJ VWHSV
6WHS
$FWLRQ
5HPRYH DOO SRZHU IURP WKH FRQWURO SDQHO
EHIRUH PDNLQJ DQ\ ZLULQJ FRQQHFWLRQV
0RXQW WKH PRGXOH LQ WKH FRQWURO FDELQHW LI
VSDFH LV DYDLODEOH RU DGMDFHQW WR WKH FDELQHW
XVLQJ IDFHG DGKHVLYH WDSH
6HW WKH 3/0ªV ',3 VZLWFKHV IRU D GHYLFH
DGGUHVV EHWZHHQ DQG 6HH WKH PRGXOHªV
LQVWUXFWLRQV IRU WKH ',3 VZLWFK WDEOH
'R QRW XVH DQ DGGUHVV EHLQJ XVHG E\ DQRWKHU
GHYLFH NH\SDGV 5) UHFHLYHUV HWF
&RQQHFW WKH 9 DQG ¥ DQG GDWDRXW DQG
GDWDLQ FRQQHFWLRQV IURP WKH 3/0 WR WKH
FRQWUROªV NH\SDGV WHUPLQDOV DQG
UHVSHFWLYHO\
&RQQHFW WKH ZLUH 56 FDEOH EHWZHHQ
HDFK 3/0 5HFRPPHQGHG ZLULQJ LV WR EULQJ
WKH ZLUHV §LQ¨ IURP RQH PRGXOH RU FRQWURO
SDQHO WR WHUPLQDOV DQG * DQG
§RXW¨ WR WKH QH[W PRGXOH IURP WHUPLQDOV 7%
DQG *
+
_
G
+
_
G
+
_
1 2 3 4 5 6 7 8
PLG-002-V0
RS-485
RS-485
EOL
JUMPER
PINS
PIEZO
SOUNDER
TAMPER
REED
SWITCH
DIP
SWITCH
ECP IN
ECP OUT
)LJXUH 9$ 3DQHO /LQN 0RGXOH :LULQJ
/RQJ5DQJH5DGLR&RQQHFWHGWRWKH-7ULJJHUV
7KHVH WULJJHUV PD\ EH XVHG WR WULS DX[LOLDU\ DODUP
VLJQDOLQJ HTXLSPHQW VXFK DV $'(0&2ªV
8/) DQG 6( /RQJ 5DQJH 5DGLRV
7KH WULJJHUV DUH FRPPRQ WR DOO SDUWLWLRQV DQG PXVW EH
HQDEOHG IRU HDFK SDUWLWLRQ ILHOG
✳
7KH ILUH DQG EXUJODU\DXGLEOH SDQLF DODUP WULJJHUV DUH
QRUPDOO\ /2: DQG JR +,*+ XQWLO D 8VHU &RGH 2))
LV HQWHUHG LQ DOO HQDEOHG SDUWLWLRQV WKDW GLVSOD\ WKHVH
FRQGLWLRQV
7KH VLOHQW SDQLFGXUHVV WULJJHU O,*+ H[FHSW
IRU GXUHVV ZKLFK LV PRPHQWDU\
7720 ULF RADIO
SEE 7720 ULF INSTRUCTIONS FOR
MORE DETAILED INSTALLATION
INFORMATION
FA
U
LT
4142TR
CABLE
FAULT
FAULT
ZONE 1
ZONE 2
ZONE 3
GR
OUND
RED FIRE ALARM
BROWN BURG / AUDIBLE PANIC ALARM
BLACK SILENT PANIC / DURESS ALARM
J7 CONNECTOR
NOTE 2: MOUNT THE 7720 WITHIN 3 FEET OF THE C-COM. RUN WIRING FROM C-COM TO 7720 IN CONDUIT.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
- CUT RESISTOR JUMPERS Z1-Z3.
- DO NOT USE 2k EOL RESISTOR.
- PROGRAM 7720 ULF FOR SLAVE
OPERATION. PROGRAM ZONES 1-3
AS ALARM ZONES
J5
1
5
3
8
4
9
2
7
6
GRAY GROUND
GRAY
NOTE 1: CONNECT TO CONTROL PANEL'S HARDWIRE ZONES (2-8) USE 2K EOLR
RADIO FAULT
(PROGRAM FOR
SHORT ON FAULT)
SEE NOTE 1
7720ULF_1
)LJXUH &RQQHFWLRQV WR 8/)
Summary of Contents for FA1660C
Page 2: ... ...
Page 18: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 76: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 98: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 114: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 118: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 128: ... 4l LOHHQ D 6 RVVHW 1 KWWS ILUVWDOHUWSUR FRP RS ULJKW 3 77 25325 7 21 ...