6HFWLRQ ,QVWDOOLQJ WKH &RQWURO
:LULQJ :LUH 6PRNH 'HWHFWRUV
8/
3RZHU WR ZLUH VPRNH GHWHFWRUV PXVW EH
VXSHUYLVHG ZLWK DQ (2/ GHYLFH XVH D 6\VWHP
6HQVRU $% (2/ UHOD\ PRGXOH
FRQQHFWHG DV VKRZQ LQ )LJXUH
7R ZLUH ZLUH VPRNH GHWHFWRUV WR ]RQHV SHUIRUP
WKH IROORZLQJ VWHSV
6WHS
$FWLRQ
6HOHFW ZLUH VPRNH GHWHFWRUV VHH OLVW RI
FRPSDWLEOH GHWHFWRUV VKRZQ SUHYLRXVO\ LQ
WKLV VHFWLRQ
&RQQHFW GHWHFWRUV LQFOXGLQJ KHDW GHWHFWRUV
LI XVHG DFURVV WHUPLQDOV RI WKH ]RQH
VHOHFWHG $OO GHWHFWRUV PXVW EH ZLUHG LQ
SDUDOOHO 6HH )LJXUH
127( ,I \RX DUH XVLQJ WKH - RXWSXW
WULJJHU WR UHVHW WKH VPRNH GHWHFWRUV UHIHU WR
WKH - 7ULJJHU 2XWSXWV VHFWLRQ IRU WKH ZLULQJ
LQVWUXFWLRQV
&RQQHFW WKH (2/5 DW WKH ODVW GHWHFWRU LQ WKH
ORRS DFURVV WKH ]RQHªV WHUPLQDOV <RX PXVW
FRQQHFW WKH (2/5 DFURVV WKH ORRS ZLUHV
DW WKH ODVW GHWHFWRU
+
_
+
_
+
+
_
_
_
+
HEAT
DETECTOR
4-WIRE
SMOKE
DETECTORS
V128BP-002-V0
NO CONNECTION
C
NC
NO
RESET
RELAY 1, 2, 3, OR 4
4204 RELAY MODULE
NOTES:
· PROGRAM THE RELAY TO
TRANSFER ON FIRE ZONE
RESET (ACTIVATION CODE 54).
SEE 4204 RELAY MODULE
SECTION FOR DETAILS.
· SECOND CODE AND OFF
ENTERED AT CONSOLE
MOMENTARILY INTERRUPTS
DETECTOR POWER.
SHOWN POWERED.
RELAY OPENS WHEN
POWER IS LOST.
EOL POWER
SUPERVISION
RELAY MODULE
A77-716B
2k
EOLR
TO
FIRE ZONE
TERMINALS
TO
AUXILIARY
POWER
TERMINALS
)LJXUH :LUH 6PRNH 'HWHFWRUV
8VLQJ 6PRNH 3RZHU 5HYHUVDO 0RGXOH
7KH 350 3RODULW\ 5HYHUVLQJ 0RGXOH LV XVHG WR
UHYHUVH WKH SRODULW\ RI WKH SRVLWLYH DQG QHJDWLYH
YROWDJHV SRZHULQJ VPRNH GHWHFWRUV 7KH PRGXOH LV IRU
XVH ZLWK ZLUH VPRNH GHWHFWRUV WKDW HPSOR\ D VRXQGHU
DQG YROWDJHUHYHUVLQJ IHDWXUH 7KH PRGXOH LV WULJJHUHG
E\ D SXOVLQJ EHOO RXWSXW
6PRNH 'HWHFWRUV &RPSDWLEOH ZLWK WKH 350
7KH 350 PD\ EH XVHG ZLWK WKH 6\VWHP 6HQVRU
$7 DQG VLPLODU PRGHOV ZLWK WKH UHTXLUHG
RSHUDWLQJ IHDWXUHV SUHYLRXVO\ VWDWHG
7KH 350 UHYHUVHV SRODULW\ WR VPRNH
GHWHFWRUV ZLWK ,QWHJUDO 7HPS 6RXQGHUV
7\SLFDOO\ LQ DODUP HDFK GUDZV P$ RI
FXUUHQW 7KH FRQWURO SDQHO VXSSOLHV RQO\
HQRXJK FXUUHQW IRU RQH VPRNH GHWHFWRU ,Q
RUGHU WR DWWDFK PRUH WKDQ RQH DQ H[WHUQDO
SRZHU VXSSO\ DQG DQ H[WHUQDO UHOD\ PD\ EH
UHTXLUHG
,QVWDOOLQJ WKH 350
0RXQW WKH 350 LQVLGH WKH FRQWURO SDQHOªV FDELQHW
RU LQ D VHSDUDWH FDELQHW XVLQJ WKH GRXEOHVLGHG WDSH
SURYLGHG :LUH WKH 350 DV VKRZQ LQ )LJXUH
5HIHU WR WKH 350 ,QVWDOODWLRQ ,QVWUXFWLRQV IRU
GHWDLOHG LQIRUPDWLRQ RQ WKH LQVWDOODWLRQ RI WKH PRGXOH
PO
WER
SUPPL
Y
USE A 12VDC,
BATTERY-BACKED,
UL LISTED POWER
SUPPLY.
8
7
6
5
4
3
2
1
Jumper
333 PRM
P1
+
+
+
+
FOUR-WIRE DETECTOR CIRCUIT
+
TO FIRE ZONE
TERMINALS
HEAT
DETECTOR
EOL POWER
SUPERVISION
RELAY MODULE
A77-716B
4-WIRE
SMOKE
DETECTORS
JUMPER P1 ON
333 MODULE
MUST BE IN
"B" POSITION
4204
1
2
3
4
12
4204 MODULE
or
N.C. MOMENTARY
SWITCH
7
6
4
CONTROL PANEL
SHOWN POWERED.
RELAY OPENS WHEN
POWER IS LOST.
2k
EOLR
+
)LJXUH :LULQJ :LUH 6PRNH 'HWHFWRUV WR D
350
Summary of Contents for FA1660C
Page 2: ... ...
Page 18: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 76: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 98: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 114: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 118: ... QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 128: ... 4l LOHHQ D 6 RVVHW 1 KWWS ILUVWDOHUWSUR FRP RS ULJKW 3 77 25325 7 21 ...