NOTICE

When Fireye products are combined with equipment manufactured by others and/or integrated into
systems designed or manufactured by others, the Fireye warranty, as stated in its General Terms and
Conditions of Sale, pertains only to the Fireye products and not to any other equipment or to the
combined system or its overall performance.

WARRANTIES

FIREYE guarantees for 

one year from the date of installation or 18 months from date of manufacture

of its products to replace, or, at its option, to repair any product or part thereof (except lamps, elec-
tronic tubes and photocells) which is found defective in material or workmanship or which otherwise
fails to conform to the description of the product on the face of its sales order. 

THE FOREGOING

IS IN LIEU OF ALL OTHER WARRANTIES AND FIREYE MAKES NO WARRANTY OF
MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED.

 Except as

specifically stated in these general terms and conditions of sale, remedies with respect to any product
or part number manufactured or sold by Fireye shall be limited exclusively to the right to replace-
ment or repair as above provided. In no event shall Fireye be liable for consequential or special dam-
ages of any nature that may arise in connection with such product or part.

FIREYE 

M-4000

3 Manchester Road

APRIL 16, 2013

Derry, New Hampshire 03038

Supersedes July 15, 2011

www.fireye.com

Summary of Contents for M4RT1

Page 1: ...e Failure Response Time F F R T is fixed at three seconds LED indicator lights indicate the operat ing status of the control In the event of ignition failure or following a safety shutdown the unit lo...

Page 2: ...D1 1000K8 24 inch flame rod 1 2 NPT connector MAXIMUM MINIMUM Control 125 F 52 C 40 F 40 C Flame Rod Tip 2460 F 1500 F 816 C 40 F 40 C Fireye Terminal Typical Load Maximum Rating 120V 60 Hz 3 or 4 Ind...

Page 3: ...of an overload condition on Terminals 3 4 or 5 To replace the fuse remove power from the system Using a small screwdriver or similar tool remove the fuse from its holder Install a Fireye replacement f...

Page 4: ...tly over the pilot or main burner nozzle WIRING OF FLAME RODS For proper operation of flame rectification systems it is necessary to maintain at least 20 megohms insulating resistance in the flame rec...

Page 5: ...could result in an unsafe condition hazardous to life and property PROGRAMMER JUMPER SETTINGS The M4RT1 has a series of 8 jumpers that are used to configure the Purge timing Pilot Trial for Igni tion...

Page 6: ...is energized APPLICATION AND FUNCTION The M4RT1 provides prepurge ignition and flame safeguard for heating and process gas fired burn ers The recycle or non recycle operation is determined by the 8 ju...

Page 7: ...ers Recycle Operation With jumper 8 in the recycle position the typical wiring arrangement illustrated on pages 10 and 11 for direct spark ignited burners provides the following function 1 With power...

Page 8: ...eading between 4 and 10 micro amps Flame Signal Testing 1 Manually shut off the main fuel valve for a pilot ignited burner or the secondary fuel valve for a direct spark ignited burner 2 Set the test...

Page 9: ...e installation Realign the flame detector so that pilot flame detection requires a larger pilot flame Repeat this test until the main flame lights reliably with minimum pilot WARNING The minimum pilot...

Page 10: ...T SWITCHES OPERATING CONTROL FUEL INTERLOCKS 7 BURNER MOTOR OR CONTACTOR 8 2 A 6 LOCKOUT ALARM KB KA AIR FLOW SWITCH ELECTRONIC CIRCUIT KL KF S1 S2 3 5 4 FLAME AMPLIFIER KL 1 KF 1 KF 2 PILOT MAIN SPAR...

Page 11: ...BURNER FIRES S2 3 5 4 IGNITION 7 8 2 A 6 PILOT S1 B MULTIPLE BURNER SYSTEMS S2 3 5 4 IGNITION 7 8 2 A 6 PILOT S1 LIMIT R MANUAL RESET MAIN GAS VALVE ALARM S P D T RA ALARM SILENCE SWITCH G R STOP STAR...

Page 12: ...h is found defective in material or workmanship or which otherwise fails to conform to the description of the product on the face of its sales order THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES AN...

Reviews: