4

This unit cannot be used in recreational vehicle applications.

How to Install Your CO Alarm

Once you have decided the best place to install the CO alarm(s), follow 
these steps:

1. Locate a standard household electrical outlet that is not blocked by drapes, 

furniture, or other items. Be sure the outlet is not near air exchange vents.

This CO alarm is designed to plug directly into a standard 120 VAC, 60 Hz
household outlet, which can supply at least 0.05 Amp of current.

DO NOT INSTALL IN A WALL SWITCH-CONTROLLED OUTLET.

2. IMPORTANT: Your CO alarm will mount to a horizontally or vertically oriented 

outlet (see Figure 4). Rotate the 90° rotating plug for the correct outlet 
orientation before plugging into outlet (see Figure 5). CO alarm must be installed
and used so that it hangs vertically once in outlet.

3. Plug the CO alarm directly into the chosen electrical outlet. The ON light will remain lit

indicating the CO alarm is receiving power and operating normally.

4. Press the test/reset button, (see Figure 6). The alarm should sound a short tone. Once

the button is released, the CO alarm will go through its test cycle turning on the amber
service light and flashing the alarm light. The alarm will beep four times followed by 5
seconds of silence and then repeat the cycle.

5. Your CO alarm has an Alarm Action Guide in English installed on the back of the

alarm. If you prefer, the enclosed Spanish version can be installed by removing the
English version and inserting the Spanish version in the slide-out panel. If your unit 
has Spanish labels included, simply place the labels over the English version.

6. Two self-adhesive labels have been provided with instructions indicating what to do if

the alarm sounds. Add the phone numbers of your emergency services provider and
a qualified technician to each label. Place one of the labels in a visible area next to the
alarm, and place the other label near a source of fresh air which will be used as a
gathering place if the alarm sounds.

UNIT WILL NOT OPERATE DURING POWER FAILURE.

DO NOT use with extension cords, or attempt to hardwire this unit directly to the
household electrical current. The CO alarm WILL NOT work properly and this will
void your warranty.

FIGURE 5

FIGURE 6

WARNING

!

WARNING

!

FIGURE 4

NOTE: Your CO alarm must always
be aligned and used in the vertical
position once in the outlet, as
shown above.

WARNING

!

WARNING

!

WARNING

!

TEST/RESET

BUTTON

Rotatable Plug

Rotatable Plug

(rear view)

Summary of Contents for COQ1

Page 1: ...means greater security and peace of mind for you and your family The Maple Chase Company 2 The Dangers of Carbon Monoxide CO 2 CO Alarm Features 3 Where to Install Your CO Alarm 4 How to Install Your...

Page 2: ...alarm and for important safety tips to safeguard your family from deadly CO poisoning The following symbols identify the most important safety messages in this manual When you see this symbol be awar...

Page 3: ...vel of the home where household members frequently spend time as well as in the basement See Figures 1 2 and 3 for typical CO alarm locations within the home This alarm will only indicate the presence...

Page 4: ...g on the amber service light and flashing the alarm light The alarm will beep four times followed by 5 seconds of silence and then repeat the cycle 5 Your CO alarm has an Alarm Action Guide in English...

Page 5: ...me quiet for approximately four minutes The alarm signals will be reenergized within 4 minutes from the time the reset button is pressed if the concentration of carbon monoxide surrounding the alarm r...

Page 6: ...more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in an attached garage or adjacent to the residence If the CO alarm sounds its ala...

Page 7: ...ration of CO and its effect over time Conditions That Can Cause CO Levels To Change The following conditions can result in transient CO situations in the home 1 Excessive spillage or reverse venting o...

Page 8: ...he nature of the difficulty and proof of date of purchase to Maple Chase Company of Canada Product Service Department 5785 Kennedy Road Mississauga Ontario L4Z 2G3 Technical Service 800 779 1719 M F 7...

Page 9: ...rit The Maple Chase Company 10 Les dangers du monoxyde de carbone 10 Caract ristiques du d tecteur de CO 11 O installer votre d tecteur de CO 12 Comment installer votre d tecteur de CO 13 Fonctionneme...

Page 10: ...curit importants pour prot ger votre famille des risques d empoisonnement mortel au CO Dans le pr sent guide les consignes de s curit les plus importantes sont identifi es par les symboles suivants D...

Page 11: ...Vous trouverez des exemples d installations types aux Figures 1 2 et 3 ci dessous ATTENTION Le d tecteur d c le seulement la pr sence de monoxyde de carbone au niveau du capteur Du CO pourrait s tre a...

Page 12: ...ertisseur entame une s quence diagnostique le voyant service jaune s allume le voyant alarm rouge clignote L avertisseur reten tit quatre reprises puis reste silencieux pendant 5 secondes La s quence...

Page 13: ...ez alors sur le bouton Test Reset l avertisseur reste silencieux pen dant environ quatre minutes Les signaux sonores et lumineux seront r activ s apr s quatre minutes si la concentration de monoxyde d...

Page 14: ...pour plus d information sur les risques de production de CO par l ap pareil V rifiez qu il n y a pas de v hicule motoris en marche au ralenti dans un garage attenant ou proximit de votre logement AVE...

Page 15: ...en fonction du temps et du taux de CO dans l air ambiant Facteurs affectant la concentration de CO dans l air ambiant Les facteurs suivants peuvent causer une accumulation transitoire de CO dans votr...

Page 16: ...n d uvre et ce pendant une p riode de cinq 5 ans compter de la date d achat dans des conditions normales d utilisation et d entretien Maple Chase Company accepte sa discr tion de r parer ou remplacer...

Reviews: