background image

FIRESTORM

 

SEQ18 / SEQ36

 

USER GUIDE

 

 

Summary of Contents for SEQ18

Page 1: ...FIRESTORM SEQ18 SEQ36 USER GUIDE...

Page 2: ...Example 2 4 Clock Mode 5 Example 1 5 Example 2 5 Example 3 5 Step Mode 6 Burst Mode 6 Setup 7 Memory 7 General Operation 8 Controls 8 Menu 8 Method of operation 9 TIPS 9 Trigger Input 10 Fire Button...

Page 3: ...rrent 25mA No Trigger 35mA Guaranteed Trigger Operating Modes Equal Different Clock Step Burst DESCRIPTION The FireStorm SEQ18 SEQ36 are highly flexible pyrotechnic firework and SFX sequencers They ar...

Page 4: ...or longer sequences Example 1 1 Group of 18 Channels Channel 1 18 will fire with 1 5 seconds between each channel when the 1st Trigger Input is received Trigger Output will then fire on each successiv...

Page 5: ...4 06 3rd Channel 07 09 4th Channel 10 12 5th Channel 13 15 6th Channel 16 18 then Trigger Out 9x2 1st Channel 01 02 2nd Channel 03 04 3rd Channel 05 06 4th Channel 07 08 5th Channel 09 10 6th Channel...

Page 6: ...ill fire 2 35 seconds after the Trigger Input is received Example 3 Channel 3 will fire 6 seconds after the Trigger Input is received Note Channels do not have to fire in order For example Channel 2 c...

Page 7: ...GER START CHANNEL END CHANNEL DELAY DESCRIPTION T01 01 12 0 05s The 1st trigger pulse fires channel 1 to 12 with 0 05 seconds between channels T02 13 14 2 00s The 2nd trigger pulse fires channel 13 to...

Page 8: ...lays can be saved in each mode This allows commonly used sequences to be stored for future use Note The sequencer will automatically store the current setup If the sequencer is powered off and on it w...

Page 9: ...into preset groups 2 Different Set relative interval between channels 2 1 Setup Setup a series of intervals 2 2 Load Show Load a stored series of intervals 2 3 Clear Show Clear a stored series of inte...

Page 10: ...ot fire many cues at the same time overlapping cues The total current available is limited to about 4 Amps per block of 18 channels to protect the internal circuitry To fire many channels at once we r...

Page 11: ...e Button Trigger The sequencer can be triggered by pressing the FIRE button on the front panel Current Trigger Current from an external firing system or our dedicated trigger unit can trigger the sequ...

Page 12: ...cond sequencer and so on The Trigger Output LED will light whenever there is a Trigger Output pulse Example 1 3 x 18 shot sequencers all in STEP mode require 3 x 18 54 Trigger Input pulses to fire all...

Page 13: ...sed Note The battery voltage should be above 23V for best operation SELF TEST ERROR CODES The sequencer runs a self test on start up This may warn you of defects by displaying an error code Pressing O...

Page 14: ...13 of 13...

Reviews: