![FireplaceXtrordinair 36 DV EFIII Owner'S Manual Download Page 9](http://html1.mh-extra.com/html/fireplacextrordinair/36-dv-efiii/36-dv-efiii_owners-manual_2291976009.webp)
I
NSTALLATION
(C
ONT
.)
P
AGE
9
+
Facing may be installed so it inserts behind the faceplate but not below it (see illustration below).
+
To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing
directly next to the fireplace. See the illustration below.
1/2" Drywall
1/2" Concrete Board
3/8" Tile
This 2x4 is recessed 3/8"
to make a flush facing
Faceplate
Fireplace
1"
Fireplace
1/2" Drywall
1/2" Concrete Board
3/8" Tile
The tile overlaps the drywall
for an overlap facing
Faceplate
1"
TOP
VIEW
Nail Down
Flange
Nail Down
Flange
Mantel Requirements
•
The optional mantel must be a min. 24" above the top of the faceplate (54" above the base).
Hearth Requirements
•
The hearth must extend 16" in
front of the faceplate. It must
also match the width of the
faceplate (36" wide, centered on
the fireplace).
•
The hearth must be made of a
non-combustible material at
least 3/8" thick (it must not raise
more than 7/8" above the base of
the fireplace).
24"
54"
Mantel (may be
combustible)
Minimum
Mantel
Clearance
16"
Minimum Hearth
Depth (must be
36" wide)