Gas Line Install
!
The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1
and the requirements listed below.
!
The fireplace and gas control valve must be disconnected from the gas supply piping during any
pressure testing of that system at test pressures in excess of 1/2 psig. For pressures under 1/2 psig,
isolate the gas supply piping by closing the manual shutoff valve.
•
The gas line must be properly purged to release all air in the gas line prior to starting the fireplace.
•
Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.
Fuel
•
This fireplace is designed either for natural gas or for propane (but not for both). Check the sticker
on the top of the gas control valve to make sure the correct fuel is used.
Gas Line Connection
•
The gas inlet accepts a 3/8" M.P.T. or 1/2" F.P.T.
•
The location of the gas inlet is shown below (connect to the flex tube)
+
A manual shutoff valve is required (it may be installed behind the access door inside the fireplace)