I
NSTALLATION
(C
ONT
.)
P
AGE
25
8
Start the fireplace and let it burn for fifteen minutes. Adjust the air shutter, if necessary, to achieve a
correct flame (see the illustration below).
•
The air shutter adjusts the amount of air that mixes with the gas before it exits the burner holes.
It is used to fine-tune the flame for differences in altitude and vent configuration.
•
If the air shutter is in its upward most position, yet the flames remain sooty, shut off gas to the
fireplace and contact a qualified gas service technician to remedy the situation.
!
If the vent configuration is installed incorrectly the vent may cause the flames inside the fireplace
to lift or "ghost" – a dangerous situation. Inspect the flames after installation to insure proper
performance. If the vent configuration is correct, yet the flames are lifting or ghosting, shut off
gas to the fireplace and contact the dealer for information on remedying the problem.
The flames should burn right off
the top of the burner ports (if they
are too blue, adjust the air control).
If the flames are lifting, yet the
vent configuration is correct,
contact Travis Industries.
Burner Pan
Burner Ports
(consists of slots
and holes)
If the flames are ghosting, yet the
vent configuration is correct,
contact Travis Industries.
9
Give this manual to the home owner and fully explain the operation of the fireplace.