2.   INSTALLATION RESPONSIBILITIES 

 

WARNING:

 THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED 

IN ACCORDANCE WITH AS/NZ 2918 AND THE APPROPRIATE 
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. 
 
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN 
APPROVED IN WRITING BY THE TESTING AUTHORITY IS 
CONSIDERED 
TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE 
WITH AS/NZS 4013. 

 

CAUTION:

  MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM 

DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION 
OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS.  WHERE 
SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE 
CONSULTED IN THE FIRST INSTANCE. 
 
Strict adherence to these instructions will meet these standards. 
Any variation from these installation instructions or any doubt about them must be 
checked against the requirements of the Standards. 
 

Please leave this manual with the owner when installation is complete

 
 
 

3.   FLOOR PROTECTOR REQUIREMENTS 

 
The heater should always be installed on top of its base due to high temperatures 
sustained over long periods.  The base must be anchored to both the floor protector and 
the floor for seismic restraint.  Anchor points are provided in the base.  
 
If the heater is installed on or within 500mm of a heat sensitive floor, 

then an ash 

floor

 

protector using a minimum of 6mm thick tiles will be required

.

  This 

floor protector shall extend under the appliance and not less than 300mm beyond the 
front of the fuel loading or ash removal openings.  The width of the floor protector 
shall be not less than the width of the appliance, and shall extend not less than 200mm 
from each side of the fuel loading or ash removal openings unless it forms an abutment 
with a wall or heat shield at a lesser distance. 
 
Where the floor protector consists of a number of components, it shall include a 
continuous layer of heat-resistant material extending under the appliance to the 
perimeter of the floor protector.  All joints shall be fixed to prevent accidental 
separation, and shall be sealed to prevent any spilt ash or embers contacting any heat 
sensitive material. 
 
 
 
 

Summary of Contents for Viking AG

Page 1: ...WET WET AG Clean Air FREESTANDING WOODBURNER All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit...

Page 2: ...llation is complete INDEX Page No Item No Topic 3 1 Warnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 6 Wetback 8 7 Fl...

Page 3: ...AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its peak...

Page 4: ...IREMENTS The heater should always be installed on top of its base due to high temperatures sustained over long periods The base must be anchored to both the floor protector and the floor for seismic r...

Page 5: ...340 mm Width 320 mm Depth 500 mm Flue Size 150mm Heating Area approx 200sqm CLEARANCES A B C D E F G H J K L M N O WITH FLUE SHIELD 100 320 300 120 50 260 590 350 780 1040 1280 1060 780 410 Clearances...

Page 6: ...around the top of the firebox and ensure they are bedded down well Lifting lugs are positioned onto the sides of the casting taking care not to catch fingers under the plates 7 Assemble and install th...

Page 7: ...ith the shortest and straightest possible pipe run 2 The heater should be within 6 metres of the hot water cylinder the closer the better 3 The flow pipe from the heater to the cylinder must rise the...

Page 8: ...g screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe can either lowered from the top as a single unit or fed up fro...

Page 9: ...Viking AG Wet 9...

Page 10: ...Viking AG Wet 10 IMPORTANT UPON INSTALLATION CHECK THAT THE TRIANGULAR BRICK ON TOP OF THE BAFFLES IS PLACED AS SHOWN...

Page 11: ...itsons Limited Manufacturers of Lady Kitchener Bronte Coaster Contessa Dante Zealandia Royale Athena Forte Aqualux 68 Austin Street PO Box 3231 Onekawa Napier Phone 06 8438260 Fax 06 8430505 Email hot...

Reviews: