Firenzo Lady Kitchener AG 08 DRYBACK Installation Manual Download Page 6

Lady Kitchener AG08 Dryback 

5.   ASSEMBLY INSTRUCTIONS 

 
 
 
 
 
1.   Remove all packaging and timber. 
 
2.   Remove parts from inside the firebox. 
 
3.   Remove both front and rear top castings. 
 
4.   Make sure baffles and triangular bricks are positioned as in diagram on page 11. 
 
5.   Place pedestal/drawerbase onto floor protector, fit firebox on top of same. 
The leg model comes assembled so place complete unit on the floor protector. 
 
6.   Fit cast tops to firebox for positioning fire on floor protector taking the necessary 
final clearances into consideration.  These measurements coincide with the figures on 
page 5 - Installation Instructions. 
 
6.   Secure both fire and floor protector to floor - see Seismic Restraint page 7.  This is 
a New Zealand Standard requirement due to NZ being earthquake prone. 
 
7.   Assemble and fit flue as per instructions (page 8 & 9) 
 
8.  A flue pipe shield 

must

 be fitted.  The minimum requirement is for a single skin, 

semi-circular, stainless steel flue shield with a reflective inner surface 1200mm high.  
This should be installed so that the bottom edge of the flue shield is at the same level 
as the top of the flue spigot and spaced off the flue pipe by approximately 35mm. 
  
9.   Assemble and fit the gold/silver/black rails. 
 
10.  Fit door knob with spacer as per drawing shown herewith - 
 
11.  Fit the air control knob - place the flat on the knob to the flat 
 on the shaft situated on the right hand side of the fire.  
 Press home firmly. 
 
 
 
 
 
 
 

 
 

 

Summary of Contents for Lady Kitchener AG 08 DRYBACK

Page 1: ...All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior to commencing the installation Failure...

Page 2: ...arnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 Fitting Seismic Restraints 8 6 Flue Installation 9 Minimum Height of...

Page 3: ...LAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is a...

Page 4: ...from these installation instructions or any doubt about them must be checked against the requirements of the Standards Please leave this manual with the owner when installation is complete 3 FLOOR PR...

Page 5: ...PTH FOR PED OR D BASE 554 470 444 412 389 360 334 306 F P DEPTH FOR LEG BASE 300 300 300 300 300 300 300 300 4 INSTALLATION CLEARANCES When installing the Lady Kitchener AG on a leg base ADD 70mm to v...

Page 6: ...ructions 6 Secure both fire and floor protector to floor see Seismic Restraint page 7 This is a New Zealand Standard requirement due to NZ being earthquake prone 7 Assemble and fit flue as per instruc...

Page 7: ...SE MODELS 1 Remove bolts at rear of fire box 2 Fit Seismic Restraint brackets 3 Secure both the floor protector and the appliance to the floor LEG MODELS 1 Place firebox on leg assembly and fit bracke...

Page 8: ...ards Fix each joint with three stainless rivets or self tapping screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe...

Page 9: ...Lady Kitchener AG08 Dryback 9 WARNING The appliance and flue system shall be installed in accordance with AS NZS 2918 2001 and the appropriate requirements of the relevant building code or codes...

Page 10: ...Lady Kitchener AG08 Dryback 10 LADY KITCHENER AG08 DRY IMPORTANT UPON INSTALLATION CHECK THAT THE TRIANGULAR BRICKS ON TOP OF THE BAFFLES ARE PLACED AS SHOWN B A F F L E S...

Page 11: ...ons Limited Manufacturers of Lady Kitchener Bronte Contessa Royale Zealandia Encore Coaster Athena Forte Deco Plaza Aqualux Kompact 98 Niven Street Onekawa PO Box 3231 Napier 4142 Phone 06 8438260 Fax...

Reviews: