2.   INSTALLATION RESPONSIBILITIES 

 

WARNING:

 THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED 

IN ACCORDANCE WITH AS/NZ 2918 AND THE APPROPRIATE 
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. 
 
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN 
APPROVED IN WRITING BY THE TESTING AUTHORITY IS 
CONSIDERED 
TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE 
WITH AS/NZS 4013. 

 

CAUTION:

  MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM 

DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION 
OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS.  WHERE 
SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE 
CONSULTED IN THE FIRST INSTANCE. 
 
Strict adherence to these instructions will meet these standards. 
Any variation from these installation instructions or any doubt about them must be 
checked against the requirements of the Standards. 
 

Please leave this manual with the owner when installation is complete

 
 
 
 

3.   FLOOR PROTECTOR REQUIREMENTS 

 
The heater should always be installed on top of its base due to high temperatures 
sustained over long periods.  The base must be anchored to both the floor protector and 
the floor for seismic restraint.  Anchor points are provided in the base or on the rear 
legs. 
 

PEDESTAL, DRAWER BASE & LEGS MODELS

If the heater is to be placed on or within 500mm of a heat sensitive floor, an

 

insulated

 

floor protector

 with a minimum thickness of 

40mm

 is required 

consisting of 20mm of an approved insulation material i.e. 2 sheets of 10mm 
micorboard or superlux, 10mm tile backing board and 10mm tiles or similar on the top 
surface. All joints on the upper surface should be sealed to prevent spilt ash from 
contacting any heat-sensitive material.  
 

Summary of Contents for Lady Kitchener AG 08 DRYBACK

Page 1: ...All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior to commencing the installation Failure...

Page 2: ...arnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 Fitting Seismic Restraints 8 6 Flue Installation 9 Minimum Height of...

Page 3: ...LAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is a...

Page 4: ...from these installation instructions or any doubt about them must be checked against the requirements of the Standards Please leave this manual with the owner when installation is complete 3 FLOOR PR...

Page 5: ...PTH FOR PED OR D BASE 554 470 444 412 389 360 334 306 F P DEPTH FOR LEG BASE 300 300 300 300 300 300 300 300 4 INSTALLATION CLEARANCES When installing the Lady Kitchener AG on a leg base ADD 70mm to v...

Page 6: ...ructions 6 Secure both fire and floor protector to floor see Seismic Restraint page 7 This is a New Zealand Standard requirement due to NZ being earthquake prone 7 Assemble and fit flue as per instruc...

Page 7: ...SE MODELS 1 Remove bolts at rear of fire box 2 Fit Seismic Restraint brackets 3 Secure both the floor protector and the appliance to the floor LEG MODELS 1 Place firebox on leg assembly and fit bracke...

Page 8: ...ards Fix each joint with three stainless rivets or self tapping screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe...

Page 9: ...Lady Kitchener AG08 Dryback 9 WARNING The appliance and flue system shall be installed in accordance with AS NZS 2918 2001 and the appropriate requirements of the relevant building code or codes...

Page 10: ...Lady Kitchener AG08 Dryback 10 LADY KITCHENER AG08 DRY IMPORTANT UPON INSTALLATION CHECK THAT THE TRIANGULAR BRICKS ON TOP OF THE BAFFLES ARE PLACED AS SHOWN B A F F L E S...

Page 11: ...ons Limited Manufacturers of Lady Kitchener Bronte Contessa Royale Zealandia Encore Coaster Athena Forte Deco Plaza Aqualux Kompact 98 Niven Street Onekawa PO Box 3231 Napier 4142 Phone 06 8438260 Fax...

Reviews: