Lady Kitchener AG08 Dryback
5
FLOOR PROTECTOR DIMENSIONS:
Refer to drawings under 4.Installation Clearances.
The standard front clearance from the front of the door glass can be reduced by
increasing the insulated floor protector height, as tabled below:
FLOOR PROTECTOR HEIGHT
0
40
50
60
75
90
100
112
F/P DEPTH FOR PED OR D/BASE
554
470
444
412
389
360
334
306
F/P DEPTH FOR LEG BASE
300
300
300
300
300
300
300
300
4. INSTALLATION CLEARANCES
When installing the Lady Kitchener AG on a
leg base
ADD
70mm to vertical
measurements shown here.
CLEARANCES
A
B
C
D
E
F
G
H
J
K
L
M
N
O
ON PED OR
DRAWER
100
385
470
100
150
270
640
450
710
1220
1590
1340
950
540
ON LEGS
100
385
300
100
150
270
640
450
710
1050
1420
1200
780
540
HEATER MUST BE INSTALLED WITH FLUE PIPE SHIELD
Clearances are to a heat sensitive material.