FLOOR PROTECTOR DIMENSIONS: 

Refer to drawings under  4.Installation Clearances. 
 
The standard front clearance from the front of the door glass can be reduced by 
increasing the insulated floor protector height, as tabled below: 
 

FLOOR PROTECTOR HEIGHT 

40 

50 

60 

75 

90 

100 

112 

F/P DEPTH FOR PED OR D/BASE 

554 

470 

444  

412 

389 

360 

334 

306 

F/P DEPTH FOR LEG BASE 

300 

300 

300 

300 

300 

300 

300 

300 

 
 

4.   INSTALLATION CLEARANCES 

 
When installing the Lady Kitchener AG on a 

leg base

 

ADD

 70mm to vertical 

measurements shown here. 
 

 

 
 

CLEARANCES 

ON PED OR 

DRAWER 

100 

385 

470 

100 

150 

270 

640 

450 

710 

1220 

1590 

1340 

950 

540 

ON LEGS 

100 

385 

300 

100 

150 

270 

640 

450 

710 

1050 

1420 

1200 

780 

540 

HEATER MUST BE INSTALLED WITH FLUE PIPE SHIELD 

 

 

 

 

 

 

 

 

Clearances are to a heat sensitive material. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Lady Kitchener AG 08 DRYBACK

Page 1: ...All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior to commencing the installation Failure...

Page 2: ...arnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 Fitting Seismic Restraints 8 6 Flue Installation 9 Minimum Height of...

Page 3: ...LAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is a...

Page 4: ...from these installation instructions or any doubt about them must be checked against the requirements of the Standards Please leave this manual with the owner when installation is complete 3 FLOOR PR...

Page 5: ...PTH FOR PED OR D BASE 554 470 444 412 389 360 334 306 F P DEPTH FOR LEG BASE 300 300 300 300 300 300 300 300 4 INSTALLATION CLEARANCES When installing the Lady Kitchener AG on a leg base ADD 70mm to v...

Page 6: ...ructions 6 Secure both fire and floor protector to floor see Seismic Restraint page 7 This is a New Zealand Standard requirement due to NZ being earthquake prone 7 Assemble and fit flue as per instruc...

Page 7: ...SE MODELS 1 Remove bolts at rear of fire box 2 Fit Seismic Restraint brackets 3 Secure both the floor protector and the appliance to the floor LEG MODELS 1 Place firebox on leg assembly and fit bracke...

Page 8: ...ards Fix each joint with three stainless rivets or self tapping screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe...

Page 9: ...Lady Kitchener AG08 Dryback 9 WARNING The appliance and flue system shall be installed in accordance with AS NZS 2918 2001 and the appropriate requirements of the relevant building code or codes...

Page 10: ...Lady Kitchener AG08 Dryback 10 LADY KITCHENER AG08 DRY IMPORTANT UPON INSTALLATION CHECK THAT THE TRIANGULAR BRICKS ON TOP OF THE BAFFLES ARE PLACED AS SHOWN B A F F L E S...

Page 11: ...ons Limited Manufacturers of Lady Kitchener Bronte Contessa Royale Zealandia Encore Coaster Athena Forte Deco Plaza Aqualux Kompact 98 Niven Street Onekawa PO Box 3231 Napier 4142 Phone 06 8438260 Fax...

Reviews: