Kompact RU Installation Version 14/4/14
23
9. MANTEL CLEARANCE FOR A NON-MASONRY BUILT-IN CANOPY
If the mantel shelf on your NON-masonry fireplace is of a heat
sensitive/combustible material the minimum distance from the floor protector is as
follows. This may be reduced if a Firenzo Kompact deflector is fitted.
Heat sensitive mantle no greater than 200mm deep
A Unprotected
B With Firenzo Deflector
Kompact Diva
1180mm
Not applicable
Kompact Athena
1180mm
Not applicable
Kompact Forte
Not approved
1180mm
Kompact Deco
Not approved
1180mm
Kompact Plaza
Not approved
1180mm
Kompact Serenity
Not approved
1180mm
Non-heat sensitive/non-combustible mantle no greater than 200mm deep
A Unprotected
B With Firenzo Deflector
All Kompact fires
1180mm
Not applicable
SIDE PILLAR CLEARANCE
The minimum clearance from the side of the fascia to any heat sensitive
material must be 5mm providing the material does NOT protrude more than
150mm.
UNPROTECTED MANTEL
MINIMUM CLEARANCE
FIRENZO HEAT
DEFLECTOR FITTED
DEFLECTOR
A
B
Diagram 18
Summary of Contents for kompact ag
Page 13: ...Kompact RU Installation Version 14 4 14 13 Diagram 9 ...
Page 16: ...Kompact RU Installation Version 14 4 14 16 Diagram 12 ...
Page 19: ...Kompact RU Installation Version 14 4 14 19 Diagram 15 ...
Page 29: ...Kompact RU Installation Version 14 4 14 29 KOMPACT WITH ATHENA FASCIA ...
Page 31: ...Kompact RU Installation Version 14 4 14 31 KOMPACT WITH DECO FASCIA ...
Page 33: ...Kompact RU Installation Version 14 4 14 33 KOMPACT WITH FORTE FASCIA ...
Page 38: ...Kompact RU Installation Version 14 4 14 38 KOMPACT WITH SERENITY 4 SIDED FASCIA ...