Kompact RU Installation Version 14/4/14
21
8. FLOOR PROTECTOR REQUIREMENTS FOR A NON-
MASONRY BUILT-IN CANOPY WITH HEAT SENSITIVE FLOOR
An
Insulated
Floor
Protector (Hearth) must
consist of a minimum of
20mm
of Insulation
board (Micore 160,
Supalux, Promatech H,
Eterpan LD or product of
similar thermal
resistance) and tiles/slate
or similar with sealed
joints on top surface to
protect from spilt
ash/embers.
Dimensions A & B from above diagram must meet the following schedule:
B HEIGHT (mm) A FROM FIRE BREAST
40mm
500mm
Minimum width of floor protector must be 840mm and/or 420mm from centre of
heater.
HEAT SENSITIVE FLOOR
INSULATED FLOOR PROTECTOR
WALL
A
FASCIA
B
SUPERLUX
BUILT-IN CANOPY BOX INSULATION
BUILT IN CANOPY BOX
Diagram 17