8
firegear Outdoors KWBTO Outdoor Gas Fireplace
INSTALLATION
•
Never insulate around the body of the unit
•
Excessive heat retention in the firebox will lead to component failure
and fireplace malfunction
•
Excessive heat retention will also increase the risk of fire inside the
chase
•
Heat retention can cause “Oil-canning” and damage the fireplace due
to overheating
•
Do not build up a wall of any type in front or to the sides of the appli-
ance, higher than the firebox opening. This will create a pressure zone
at the firebox and will prevent the unit from venting
•
This is an outdoor appliance with a built-in drain. This drain should be
installed and connected in all applications as per the instructions in
this manual
•
Inadequate drainage will cause rust and reduce the life of your appli-
ance, this is not protected by warranty
•
Outdoor uniits use the same consistent, reliable Electronic compo-
nents used in most Regency “E” units
•
Installed correctly, these components will be subjected to far lower
temperatures than indoor units, which have been certified as safe from
heat etc
•
Working gas pressures are as critical in outdoor products as they are
in indoor products, even more important in Electronic systems
•
Unit shutting down intermittently
•
Overheating of components leading to failure
•
Lifting flame
•
Poor flame package (i.e. all to one side, lazy flame)
•
Failure to ignite
•
Excess carbon
•
Safety issues and concerns created from the byproducts of combus-
tion
•
Outdoor appliances must be installed in: open-air situations with natu-
ral ventilation and without stagnant areas
•
Any gas leakage and products of combustion need to be rapidly dis-
persed by wind and natural convection
•
Typically outdoor spaces are not enclosed, however, failure to adhere
to installation guidelines, may cause the outdoor fireplace to be af-
fected by wind or air pressure inside the enclosure
•
ANY
enclosure in which the appliance is used shall comply with one of
the diagrams on the previous page.
•
All walls + overhead cover = 100% total area
•
One of four walls or full overhead area must be totally open, plus—one
of remaining walls must have a fixed opening
•
All outdoor fireplaces/fire tables require total
natural
ventilation of 50%
open space
•
Correct Working Gas pressure is critical on “E” units
•
Wherever possible avoid locating on a flat wall in a tight corner
•
Floor space doesn’t count as “open area”
•
Install to the manual specs for framing and
do not insulate
unit or
enclosure
•
Framing enclosure must at least meet minimum dimensional specs as
per the installation manual
•
Only Regency approved media should be used in the firebox (i.e.
stones/glass)
•
Be aware of pressure zones due to location (i.e. facing the ocean)
•
Open walls and doorways to outside air are beneficial to the perfor-
mance of an outdoor appliance
•
Fixed roof/ceiling open areas count towards the total open area overall
requirement
•
Screens create 40% or more air restriction
•
Screened areas are restrictions and reduce open air space, calculate
area based on a
closed
screen
•
The biggest problems are created by lack of airflow for the appliance
•
Outdoor fireplaces are often built-in systems and incorrect installation
can result in high repair costs
•
Units must not be modified or altered in any way
•
There is a common misconception that being outdoors, an Outdoor
Fireplace will function, regardless of circumstances,
•
Outdoor fireplaces require the same amount of ventilation as indoor
units, often more
•
Outdoor unitis require adequate ventilation to the atmosphere, which in
turn provides ongoing circulatory combustion air
•
This type of Appliance Vents.
•
All Outdoor Fireplace Products have the same need for Air/Oxygen,
and an ability to Vent
•
Even though the appliance is outdoors, this doesn’t mean it is getting
adequate air
•
Requirements are not specific to Regency units
•
Read and follow critical location guidelines in this manual
•
•
Don’t overlook the obvious
•
Widen your margin for error
•
Combustion always requires the same three elements
•
Only the quantities and volumes change
,03257$17,1)250$7,21)25287'225),5(3/$&(,167$//$7,216
,03257$177+,1*6725(0(0%(5
$17,&,3$7(',668(6&$86('%<
,1&255(&7/2&$7,2125,167$//$7,21
287'225$33/,$1&(65(48,5(9(17,1*
&20321(176,1287'225$33/,$1&(6
&200210,6&21&(37,2165(*$5',1*
287'225),5(3/$&(6
81'(567$1',1*287'225$33/,$1&(
5(48,5(0(176
287'225$33/,$1&(,167$//$7,216800$5<