16
firegear Outdoors KWBTO Outdoor Gas Fireplace
INSTALLATION
3
PLATEAU / KEY WEST SERIES
919-227
01/09/13
12
. Attach the label "this unit has been converted to NG" near on top of the
serial # decal.
13
. Replace red "LPG" label with yellow "NG" label.
14
. Bring gas to appliance. The connector removed in previous steps can be
used on the inlet side of the regulator.
15
. Reverse steps 6-1.
16
. Check all gas connections (at valve, regulator, and NG outlet) under normal
operating pressure, for leaks, with soapy water.
NOTE
: If soap bubbles, this would indicate a gas leak.
17.
Check inlet and outlet pressures.
18
. Reinstall panels.
11
. Connect fl ex line to valve fi tting.
Connect fl ex line
to valve
Diagram 12