background image

H- Burner Kit

REV. A  Page 14

ACCESSORIES 

The following accessories are available from your local Firegear Outdoors dealer/distributor.  

Each accessory comes with a separate installation manual.  Read each instruction thoroughly before installing.

Lava Stones 1” to 2” size.

Model

: FG-LS50 (50lb. bag)

Lava Rock 1” to 2”diameter

Model

: FG-LAVA-10 (10lb. bag), 

FG-LAVA40 (40lb bag.)

Vent Kits provide 18 square inches of 

ventilation per side of enclosure

Model

: VENT-KIT-6X12 

LP Conversion Kits

    

  See page 14 for available kits.

1.  The fire pit should be inspected and cleaned before initial use at least annually by a qualified field service person.

2.  Any component that is found faulty must be replaced with an approved component.

3.  Any tampering or modifying with the fire pit is dangerous and voids all warranties.

4.  During winter months in cold climates and various seasons operation the fire pit may be affected by weather 

     conditions.  It is recommended to use a ventilated cover over top of your fire pit to protect it from humid/rainy weather       

     conditions when not in use.  Heavy rains/downpours could affect the fire pit operation if not covered; if this occurs 

     ensure you allow the fire pit time to dry out before attempting to operate.  

NOTE

: If a combustible type cover is used

     over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard.

5.  Over time stainless steel parts can discolor when heated, usually a golden or brown hue.  This discoloration is normal    

     and does not affect the performance of the appliance.

FIRE PIT MAINTENANCE 

TROUBLE SHOOTING

Symptom

  

Remedy

 

Fire pit won’t light 

1. Bleed gas line.

 

 

 

2. Ensure all gas supply lines are turned ON.

 

 

 

3. Ensure there is not too much media overtop of burner; it can inhibit gas from flowing.

 

 

 

4. Check gas pressure.

Low flame 

 

1. Ensure the base media is at least 1-inch in diameter and top media is no more than 1-inch over

 

 

 

    top of burner.

 

 

 

2. Ensure all shut-off valves and key valve is fully open.  See page 11; Figure 14 

 

 

 

3. Check gas pressure.

 

 

 

4. Check for spider webs blocking the air shutter orifice.

Water in my fire pit 

1. Excess dust/sand material from media may be blocking the weep holes to relieve water.          

 

 

                 Remove all media and unplug weep holes.  Clean or install new media free of dust and dirt.

 

 

 

2. Ensure fire pit enclosure has proper drainage for water and proper ventilation to dry out.

Manual changes often occur, ensure to check the Firegear Outdoor 

website for any recent updates and warranty information.

FOR TECHNICAL SERVICE, CALL:

Firegear Outdoors

17322 Gothard St

Huntington Beach, CA 92647

Web Site:  www.firegearoutdoors.com

(800) 966-8126

Summary of Contents for FG-H-2406SS

Page 1: ...48 X 6 Burner FG H 4806SSK 48 X 6 Burner Kit 175 000 Btu s Installation and Operating Instructions IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE Warning For Outdoor Use Only INSTALLATION PRECAUTION Fire pit burners require a minimum 18 square inches per side of cross ventilation in an enclosure Failure to provide proper ventila...

Page 2: ...t DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustmen...

Page 3: ...re feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fire feature when heavy rains high humidity and moisture are present Light t...

Page 4: ...P at the burner orifice Flex line size and proper gas pipe sizing will also affect Btu s As a result your Btu s may vary slightly from Table 2 specifications BEFORE INSTALLING A H BURNER DETERMINE PAN SIZE TO BE USED The H Burners listed above are not provided with a burner pan for installation You must provide an appropriate non combustible burner pan to install the H Burner Suggested burner pans...

Page 5: ...use a Propane tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5kPa VENTILATION FOR NON COMBUST...

Page 6: ...pe sizes required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet...

Page 7: ... provide ventilation to prevent moisture and provide an outlet for gas in the case of a gas leak 8 CAUTION A minimum of 18 square inches of cross ventilation opposite sides is required to keep the enclosure dry 9 These products are designed for outdoor use only Not approved for any indoor use or any enclosed space 10 This fire pit is designed to have Firegear Outdoors lava rock or glass media comp...

Page 8: ...h the pan See Fig 4 then install the OAS and U3 8D S to the nipple connect inlet gas line as shown in Fig 5 7 8 to 1 Inch Center Hole Fig 4 Minimum center clearance hole in burner pan ALL H BURNER MODELS H BURNER ASSEMBLY CAUTION Do not assemble the OAS and U3 8D S until you are ready to install the H Burner into the burner pan The OAS is 1 in diameter and would not fit the recommended center hole...

Page 9: ... Outdoors See replacement parts list in manual for model numbers INSTALLING KEY VALVE INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock into the burner pan Ensure the lava rock is a 1 inch diameter for proper operation Note Do not pour Lava Rock directly from bag It should be placed naturally and NOT packed in tight Loose fitting is important to ensure robust flames Be sure rocks a...

Page 10: ...ly Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non Combustible Wall Material Non Combustib...

Page 11: ... use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS Key Fig 7 Inserting Key into Valve O N O F F Fig 6 Key valve flange Butane Lighter ...

Page 12: ...Air Shutter for Natural Gas or LP Gas Fire Pits Refer to Table 2 on page 4 3 1 2 Flex Gas Line 28 inch Length used with all kits 1 T200 9898 28 4 Key Valve 1 BVL2S 4a Chrome Plated Flange Cover used with BVL2S key valve 1 CVR BVL2CP 5 12 inch Chrome Key used with all key valves 1 KEY PC 12 6 Flare to FIP U3 8D S 7 Flare to MIP U1 8D S Item Description Qty Part Number See the Firegear Outdoors cata...

Page 13: ... A 90 elbow is not provided with the kit All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound Check for any gas leaks before presuming normal operation after conversion is complete CAUTION Ensure there is ventilation under the burner to provide fresh air for air shutter orifice Burner Pan GAS FLOW x 5 inch Nipple 113SS4 D5 OAS LP Orifice Flared Fitting U3 8D S x Coupl...

Page 14: ...g to operate NOTE If a combustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Over time stainless steel parts can discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance FIRE PIT MAINTENANCE TROUBLE SHOOTING Symptom Remedy Fire pit won t l...

Page 15: ...TY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONT...

Page 16: ... BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFECTS OR ST...

Page 17: ...efect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cover any ...

Page 18: ...r consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 17322 Gothard Street Huntington Beach CA 92647 www firegearoutdoors com Phone 800...

Reviews: