Firefly Cygnus CYG2400/1380/24 User Manual Download Page 4

 

 

  

 

Cygnus  User  Manual  

-

    v3.0            2011  

 

Page  4

 

1.  Introduc on

 

1.1

 

Foreword

 

Firefly  Solar  Generators  Limited  takes  this  opportunity  to  congratulate  you  on  the  purchase  of  your  new  Cygnus  Porta-­‐
ble  Solar  Generator.

 

Designed  and  manufactured  within  the  United  Kingdom  using  only  the  finest  European  sourced  electrical  components,  
your  new  Cygnus  Portable  Solar  Generator  offers  sustainable  power  genera on  with  the  reliability  that  you  demand.

 

The  purpose  of  this  manual  is  to  introduce  you  to  the  Cygnus  Portable  Solar  Generator  and  provide  you  with  a  guide  to  
the  processes  of  se ng  up  and  opera ng  your  new  product.  This  manual  describes  how  your  Cygnus  Portable  Solar  
Generator  works,  will  help  you  with  fault  finding  and  examines  what  each  component  is  doing  and  why.

 

 

1.2

 

Conven ons

 

 

Throughout  this  user  manual  the  following  symbols  are  used:

 

1.2.1

 

Terminology

 

 
 

 

The  following  terms  are  used  in  this  manual  to  provide  greater  clarity:

 

Firefly  Solar  Generators  Ltd.  will  be  referred  to  as  “

The  manufacturer

”.

 

The  Cygnus  Portable  Solar  Generator  will  be  referred  to  as  

‘Cygnus’

  or  

‘Unit’

.

 

Any  items  that  consume  power  will  be  referred  to  as  

‘Consumers’

.

 

State  of  Charge  of  the  ba ery  bank  will  be  referred  to  as  

‘SOC’

.

 

 

1.2.2

 

Warnings

 

                W  A  R  N  I  N  G

 

This  symbol  warns  of  the  presence  of  a  dangerous  voltage  which  could  cause  harm  to  the  operator.

 

This  symbol  indicates  the  poten al  of  damage  to  the  unit  or  connected  devices.

 

This  symbol  indicates  important  or  useful  informa on.

 

This  user  manual  is  an  important  part  of  the  Cygnus  Portable  Solar  Generator.  It  must  be  kept  

 

available  to  all  operators  and  kept  close  to  the  unit  so  that  it  can  be  referred  to  at  any   me.

 

W  A  R  N  I  N  G

 

When  the  unit  is  opera ng  it  generates  poten ally  lethal  voltages.  Work  must  only  be  performed  on  
the  unit  by  the  manufacturer  or  a  qualified  service  engineer  approved  by  the  manufacturer.

 

Under  no  circumstances  should  operators  open  the  unit’s  enclosure.

 

All  items  connected  to  the  unit  including  distribu on  cables  and  boxes  should  be  regularly  checked  
and  adhere  to  the  same  local  regula ons  and  standards  as  a  regular  grid

-

ed  mains  installa on.

 

Summary of Contents for Cygnus CYG2400/1380/24

Page 1: ...ual v3 0 2011 Page 1 Cygnus Portable Solar Generator User Manual v3 0 2011 For use with the following models CYG2400 460 24 CYG2400 920 24 CYG2400 1380 24 CYG3500 920 24 CYG3500 1380 24 CYG5000 920 24...

Page 2: ...8 2 4 3 Connect the Output Power Cables 9 3 General Opera on 10 3 1 Turning the Power On 10 3 2 Monitoring the Power 11 3 2 1 Displaying Real me Ba ery Bank Voltage 11 3 2 2 Displaying the Ba ery Bank...

Page 3: ...nected to Single Cygnus 26 6 4 Appendix 4 Troubleshoo ng Guide 27 6 5 Appendix 5 Technical Data 28 6 6 Appendix 6 Further Reading 29 Figures Fig 1 Cygnus Control Panel Component Reference 7 Fig 2 RCC0...

Page 4: ...will be referred to as The manufacturer The Cygnus Portable Solar Generator will be referred to as Cygnus or Unit Any items that consume power will be referred to as Consumers State of Charge of the b...

Page 5: ...Fire y Solar generators harness energy supplied by the sun using photovoltaic PV cells storing it for when it s needed Addi onally mul charge inputs allows kine c and wind energy to be stored for conv...

Page 6: ...t weights 3 It is recommended that the unit is secured using suitable straps when in transit to prevent it from moving 2 2 2 Loading Unloading 1 Cygnus must be loaded or unloaded using the correct equ...

Page 7: ...OC C2 RCC 03 Displays real me informa on on inputs and outputs also allows their adjustment C3 Open Terminate Switch Used when mul ple Cygnus Portable Solar Generators are linked together C4 Power On...

Page 8: ...r manuals can also be downloaded from the manufacturer s website at www re ysolar net It is also possible to operate the unit only using the internal ba ery bank without external inputs connected When...

Page 9: ...ial CEEform socket for the connec on of AC power out to consumers requiring Fig 1 E2 1 Before any power connec ons are made ensure that both the RCD Fig 1 B1 and MCB Fig 1 B2 are switched O 2 Plug in...

Page 10: ...p will be heard and the RCC 03 Fig 1 C2 backlight will illuminate 5 The unit is now in standby mode 6 Message 012 use of ba ery temperature sensor will be displayed for ve seconds 7 A er which the fol...

Page 11: ...a ery life le in the unit E g C75 indicates that there is 75 ba ery capacity remaining If the 30 lower limit is reached the Smartgauge s internal alarm will be triggered and its display will ash betwe...

Page 12: ...SC on the RCC 03 Fig 1 C2 Turn the System O will be displayed 2 Press SET to accept The unit will then go into standby mode 3 To fully shut down the unit press the On O Bu on Fig 1 C4 on the control p...

Page 13: ...n the standard models The relays can ac vate external alarms and automa c start relays for second ary power systems and can be added as an op onal extra Please contact the manufacturer for further inf...

Page 14: ...he control panel If using a second Fold Array parallel junc on box to connect mul ple arrays connect its output to the Solar Array 2 connectors 6 The LED indicator to the right of the connectors will...

Page 15: ...connector from the unit Refer to Appendix 2 6 2 2 for further informa on on using the SPEC Pak connector 2 Disconnect the remaining cables and any junc on boxes 3 7 3 Charging with AC Grid Supply or S...

Page 16: ...d be set as open Fig 1 C3 rotate switch an clockwise and Cygnus 2 as Termi nated Fig 1 C3 rotate switch clockwise 4 If using three units Cygnus 1 and Cygnus 2 should be set as Open Fig 1 C3 rotate swi...

Page 17: ...and the third L3 Do not a empt to connect the units in series if this is not the case 3 Once the unit numbers have been determined posi on the three units with L1 on the le L2 in the centre and L3 on...

Page 18: ...in the On posi on and none of them have tripped out 4 4 Turning O The Units 1 Using the RCC 03 Fig 1 C2 of Cygnus 1 Press Up then Down to wake up the control panel 2 Press the Esc bu on to choose to...

Page 19: ...s can be obtained from the manufacturer 5 4 Tes ng It is recommend that the unit should be tested annually for safety by a quali ed electrician Local regula ons may require more frequent tes ng Please...

Page 20: ...to adjust the se ng 4 Use the arrow keys to input the required voltage A maximum of 245V is available Press SET to accept 5 Press ESC to navigate back to the main menu and the arrow keys to return to...

Page 21: ...e adapters and appliances 6 2 1 Connec ng the SPEC Pak Plug 1 The SPEC Pak socket is ed with a waterproof cover Fig 5 Step 1 2 Remove the cover by hinging up the retaining clip and pulling out Fig 5 S...

Page 22: ...nected to the AC output socket The ba eries are kept at full capacity and are only used if there is a break in input voltage Fig 6 Example Showing A Single Unit Connected To An AC Feed and Powering Co...

Page 23: ...sumers and any surplus power keeps the ba eries topped up Ba ery power is used when the consumers require more power than the solar arrays are genera ng Fig 7 Example Showing Arrays Directly Connected...

Page 24: ...3 3 Three Phase Cygnus System Three pre con gured units are connected by means of data cables and a series junc on box available separately from the manufacturer Fig 9 Example Showing the Use of Thre...

Page 25: ...11 Page 25 6 3 4 Two Unit Parallel Cygnus System Two units are connected by means of a data interlink cable and a parallel junc on box available separately Fig 10 Example Showing the use of Two Units...

Page 26: ...al v3 0 2011 Page 26 6 3 5 Kinectrics PedGen Connected to Single Cygnus Fig 11 Example Showing the use of Two Kinectrics Units to Charge Cygnus Fig 12 Example Showing the use of Eight Kinectrics Units...

Page 27: ...t s will automa cally switch out of this mode and the indi cators should stay on as long as power is being used Message on RCC 03 Ba ery Voltage Too Low This indicates that the voltage has reached its...

Page 28: ...Solar Generator range To nd the relevant informa on for your unit please refer to the model number on its ra ng plate at the bo om of the le hand panel or the main graphics on each side of the unit T...

Page 29: ...uso 20Xtender 20serie 20 It pdf RCC 03 English h p www studer innotec com upload temp RCC 02 03 20User 20manual pdf French h p www studer innotec com upload temp Manuel 20u lisateur 20RCC 02 03 pdf G...

Reviews: