12.6 Operation Instructions
2.6.1 RF Receiver
Operation / Alarm LED
Green LED flashing
Normal operation
Red LED flashing
(0.1s ON, 3s OFF)
Communication fault between
room thermostat and RF Receiver
Red LED flashing quickly
3 times
Faulty device
BIND LED
(ON and OFF 0.5 seconds)
Binding process
Status LED
Green LED lit
Normal operation
Green LED flashing
Communication fault between
room thermostat and RF Receiver
12.6.2 Thermostat
Explanation of the icons
Setting temperature
The figure appearing on the screen corresponds
to the setting temperature, instead of the current
room temperature.
Heating on
Heating is demanding, and thus the heat pump
should be in operation, either intermittent or
continuous.
RF Receiver connection
The thermostat is successfully connected to
the RF Receiver.
Low battery
It is necessary to replace the batteries
immediately.
RF communication error
These icons flash to indicate that the signal from
the RF Receiver is not properly received. Check
that the RF Receiver is powered on, and consult
with your installer if this does not fix the problem.
Defective thermostat
The thermostat is defective and needs to be
replaced
The text
F77
is displayed in addition to this icon
when communication with the Enviroair unit has
failed for more than 180 seconds.
No power to the thermostat
If the thermostat screen appears blank after initial
installation, then check whether the protective
film has been removed from the batteries.
Otherwise, try replacing the batteries.
Setting of room temperature
The current room temperature is shown in the display. The setting
temperature can be changed by turning the dial to the right to
increase temperature, and to the left to reduce temperature.
The setting temperature changes in 0.5 °C steps, one for each
‘click’ as the dial is turned.
Reset
To reset the stored data in order to create a new binding in
ASH000AWT press BIND button during 15 seconds.
The display changes to current room temperature again after five
seconds have passed. Then the thermostat tries to maintain the
set temperature as accurately as possible. The setting temperature
can be checked by turning the dial one ‘click’ to the left or right.
It will flash up for a few seconds, before returning to the display of
room temperature again.
Night temperature reduction
It is recommended to set the thermostat to a lower temperature
at night and during absence periods, as it helps to save energy.
In general a reduction of 5 °C is suggested, but this depends on
the heating system and the amount of insulation of the building
Installation menu
The single zone thermostat has an installation menu that is used to
set the maximum and minimum temperature limits. The maximum
temperature that can be set on the thermostat is 35 °C and the
minimum temperature is 5 °C.
Summary of Contents for Enviroair 11kW
Page 1: ...SUPERIOR HEATING SOLUTIONS SINCE 1980 Installation Operation Manual...
Page 2: ...Firebird Installation Operation Manual 2...
Page 9: ...9 5 General Dimensions Enviroair 11 16kW Enviroair 7 5kW 5 1 Service Space...
Page 54: ...Firebird Installation Operation Manual 54 Notes...
Page 55: ...55...