FEATURES

•  Thermoptek Technology - a faster response 

to slow burning and fast flaming fires 

•  Escape Light - a powerful light to 

illuminate your escape route 

•  Battery Operated 
•  Sleep Easy - silence the low battery chirp 

for 10 hours 

•  Alarm Smart Silence - silence your 

smoke alarm by momentarily pressing 
the test button, ideal for nuisance alarms   

•  Test Button - test the sounder, sensitivity, 

circuitry and battery 

•  Operating Light (RED) - flashes 

approximately every 45 seconds 
confirming alarm is powered 

•  Low Battery Warning - ‘beeps‘ 

approximately every 45 seconds for at least 
30 days when the battery needs replacing 

•  Loud 85 Decibel Piezo Electric Alarm - 

automatically resets when hazardous 
condition has passed 

•  Suitable for leisure accommodation 

vehicles (LAV)

•  Easy Installation - fixings supplied 

IMPORTANT:

 This user manual contains 

important information regarding the 

operation of your smoke alarm  Ensure 

you read this user manual fully before 

installing and operating the alarm  If you 

are installing this smoke alarm for use by 

others, you must leave this manual with 
the end user 

THERMOPTEK  

MULTI-SENSOR 

TECHNOLOGY

Thermoptek alarms are “toast-proof” 

meaning they can be positioned in areas 

close to kitchens that may be affected by 

cooking fumes  Heat alarms should be 

used in kitchens where required 

This combines an optical sensing chamber 

with thermal enhancement  The alarm is 

effective at detecting slow burning fires,  

and constant monitoring of temperature 

changes enables the sensitivity of the 

alarm to be instantly increased thereby 

quickening the typical response time to 

fast flaming fires significantly 

ESCAPE LIGHT

Your smoke alarm is fitted with an ultra 
bright LED to illuminate your escape route 
and provide a visual reference of your 
position within the home  To assist visibility 
in an emergency it is recommended that 
the alarm is positioned in a stairwell or 
hallway for a swift and safe evacuation 

The LED will last the lifetime of the alarm 
and have no negative effect on the life of 
the batteries 

POSITIONING

WARNING:

 Your smoke alarm can be 

installed into a new build property as 

additional protection to an existing smoke 

Summary of Contents for THERMOPTEK ST-623E

Page 1: ...User Manual Smoke Alarm with Escape Light Model ST 623E ...

Page 2: ...dial 1 800 523171 Email technicalsupport sprue com Web www fireangel co uk GN4590R1 ST 623E Sprue Safety Products Ltd Vanguard Centre Coventry CV4 7EZ UK A Sprue Brand 0086 CPR 676744 EN 14604 2005 AC 2008 Smoke Alarm Device DoP SAFLDOP ST 623E 01 18 BS EN 14604 2005 AC 2008 KM 676743 ...

Page 3: ...larm 6 Battery replacement 8 Note This user manual is also available in large text and other formats Please email technicalsupport sprue com or call 0800 141 2561 for further information Alarm test 9 Alarm Smart Silence 9 Sleep Easy 11 Maintenance 11 Troubleshooting 12 Disposal 14 Warranty 14 CONTENTS ...

Page 4: ...you are installing this smoke alarm for use by others you must leave this manual with the end user THERMOPTEK MULTI SENSOR TECHNOLOGY Thermoptek alarms are toast proof meaning they can be positioned in areas close to kitchens that may be affected by cooking fumes Heat alarms should be used in kitchens where required This combines an optical sensing chamber with thermal enhancement The alarm is eff...

Page 5: ...e on new builds or projects that require planning permission Your smoke alarm typically meets the minimum requirements for family living units in existing buildings as long as at least one unit is installed on each floor level of your property In order to achieve the earliest fire warning we recommend that a smoke alarm is fitted in all rooms where the temperature is normally between 4 C 40 F and ...

Page 6: ...n common areas may not provide sufficient fire warning to residents or meet regulatory requirements This smoke alarm is designed to operate as a standalone smoke alarm WARNING This smoke alarm will not communicate with other smoke alarms or fire alarm systems It is not intended as a substitute for a complete alarm system Mobile Homes and Caravans This smoke alarm is suitable for use in mobile home...

Page 7: ...Base Plate Use the fixing holes on the base plate as a guide when marking the position of the drill holes With an appropriately sized drill drill the holes and insert the plastic fixing anchors supplied if needed Fit the base plate to the ceiling or wall using the screws provided Base Plate Holes 3 FitYour Smoke Alarm Hold the alarm up to the base plate and push and rotate the alarm clockwise into...

Page 8: ...ly the following batteries can be used for replacement Use of a battery other than those recommended below may have a detrimental effect on the alarm s operation AA Alkaline type Energizer E91 Duracell MN1500 Panasonic ProPower LR6 Remove the alarm from its base plate by turning anti clockwise and pulling gently Remove the existing batteries and replace with new batteries from the recommended list...

Page 9: ... smoke alarm fails to give an audible test signal please refer immediately to Troubleshooting at the end of this manual ALARM SMART SILENCE DANGER If your smoke alarm emits the full alarm signal and you are not testing the unit the smoke alarm is warning you of a potentially dangerous situation that requires your immediate attention Only use the alarm silence function after making sure that there ...

Page 10: ...alarm silence will be overridden meaning the alarm will continue to sound and the Escape Light will continue to illuminate the event of a known false alarm your smoke alarm can be temporarily silenced by pressing the central test button Your alarm will automatically return to full sensitivity within 10 minutes a Briefly press and release the test button The alarm sound will stop and the Escape Lig...

Page 11: ...y to ensure protection in the event of a fire MAINTENANCE Your smoke alarm has been designed to be as maintenance free as possible however there are several things you must do to keep it working properly Testing Test your smoke alarm once every week see AlarmTest Any test failures should be reported to theTechnical SupportTeam Cleaning As a minimum your smoke alarm should be cleaned once every 3 m...

Page 12: ...sitivity mode it may not test Wait 15 minutes then try again If the alarm has been recently fitted and still fails to self test then contact Technical Support Your smoke alarm chirps intermittently Check the location of your smoke alarm see Positioning Check that your smoke alarm is definitely the source of chirping make sure the noise isn t coming from another alarm by process of elimination Your...

Page 13: ...u experience frequent unwanted alarms Check the location of your smoke alarm see Positioning Clean the smoke alarm see Maintenance If the frequent unwanted alarms continue contact Technical Support for advice The Escape Light does not illuminate when unit is in alarm If the Escape Light does not illuminate at all when testing or when the unit is in full alarm then contact Technical Support If you ...

Page 14: ...e disposed of with your other household waste This alarm is ideally suited for disposal within the waste electronic and electrical equipment WEEE recycling scheme Please recycle where facilities exist Check with your local authority retailer or contact our technical support team for recycling disposal advice as regional variations apply Once the batteries are removed the low battery warning chirp ...

Page 15: ...15 ...

Page 16: ......

Reviews: