9
Do not:
• Exceed the maximum of 30
interconnected alarms on a network.
• Exceed 250 m of connecting wire
per circuit.
• Connect FireAngel Pro alarms to any
other models produced by another
manufacturer.
WIRELESS INTERLINK
WST-230 and WHT-230
The WST-230 and WHT-230 are designed
to be wirelessly interlinked with up
to 50 products within the Wi-Safe 2
product range. They are not designed
to communicate with wireless alarms
from other ranges or manufacturers.
These alarms need to be ‘learned-in’ or
interlinked in order to communicate with
each other. If one alarm activates, all other
interlinked alarms will also sound.
Wi-Safe
2 eliminates the need for
interconnecting wires around a property
making future system modifications easy
and cost effective. AC Smoke and Heat
alarms will still need a mains supply
in accordance with BS 5839: Part 6 and
Building Regulations.
IMPORTANT: Obstructions such as steel
reinforcement in concrete could block
or impede the wireless signal. While the
wireless range is over 200 m in clear air /
clear line of sight, the effective range may
be reduced by walls and other obstructions
in the building. It is recommended not to
exceed 35 m as the maximum distance
between alarms in a network.
Do not:
• Exceed the maximum of 50 alarms
interlinked in a network.
• Connect FireAngel Pro alarms to
any models produced by another
manufacturer.
Mains 230V AC
Power Supply
(from upstairs circuit)
WIRING KEY
= Live
= Neutral
= Earth
= Wireless Interlink
Mains 230V AC
Power Supply
(from downstairs circuit)