Version: June 2018
3
Glass removal process
•
Note
: Glass removal is best carried out by two people.
• Carefully remove glass, which is held in place by retaining clips along the top of the glass and powerful
magnets in each lower corner.
• Remove the top retaining clips by undoing the 4mm Allen head cap
screws.
• Gently pull at the top corners in a forward motion. The glass will tilt
forward.
• In one movement gently pull the glass up and away from the fire to break the magnetic connection. Take
care that the glass doesn't fall completely off once
it’s free from the fixing magnets.
• Lift glass away from fire and lay flat in a safe place with insulating material facing down to protect glass