![Fire dept GD 12 1600 Installation Manual Download Page 15](http://html1.mh-extra.com/html/fire-dept/gd-12-1600/gd-12-1600_installation-manual_2290721015.webp)
Version: August 2020
15
Wall cowl assembly details
(for wall cowl + wall cowl fan installation)
Step 4:
Fit the front
panel
To fit the front
panel reverse
steps 1 to 3
Step 1:
Remove 5mm cap screw
Step 2:
Lift front panel
The front panel is hung on hocks
Step 3:
Remove the front panel
Fit Wall cowl into position
Step 1:
Timber framing
Set-up timber framing to suit
wall cowl.
Step 2:
Fit wall cowl into position
Fix will cowl into position
through the angle surround.
Step 3:
Flash wall cowl
Fit flashing in
accordance with NZBC.
Step 4:
Complete wall cladding
Fit wall cladding in accordance
with NZBC
Fit wall cladding into Wall cowl front panel (optional)
Step 1:
Remove front hot panel
1. Hot panel is fixed to back
panel with 4 x 5mm
counter-sunk cap screws.
Step 2:
Fix sub-straight into wall cowl
1. Cut sub-straight to suit (sub-straight not supplied)
2. The 4 x 5mm counter-sunk cap screws can be
used to hold the sub-straight in place.
Step 3:
Fix cladding into wall cowl
1. Adequately fix the cladding into the
wall cowl.