10
BATTERY CHARGER INSTALLATION
•
Install the battery charger in a ventilated and dry place, far from heat sources and corrosive
environments.
•
Make sure that the voltages are correct. Protect the mains with a delayed switch or with a load
fuse higher than the max. power consumption of the battery charter .Observe the polarity of the
battery socket(black and red cables are identified by s,-
CHOOSING THE DETERGENT SOLUTION
For a good floor cleaning, it is important to choose the proper detergent solution. If necessary, ask
the supplier or competent person for the proper solution. Keep in mind that a too strong chemical
agent can compromise the long life of each machine. It is necessary to use a low- sudsing detergent
solution, or an antifoaming additive, in order to avoid to damage the vacuum motor; if it is
impossible to get these products ,use some vinegar to avoid foam, put 50cc of it in the recovery tank
before scrubbing.
STARTING AND PREPARING THE MACHINE
If the scrubber is connected to the battery charger (having finished the charge operation),remove the
battery charger plug from the socket coming from the batteries. Then connect the batteries plug to
the machine plug (see fig. 4); then proceed with water loading by lifting up the recovery tank and
unscrew the solution tank cap
Now the machine can be used by switch on the main switch and with the operator seat on board.
Now is possible to start scrubbing.
HOW TO USE THE MACHINE
The scrubbing operation is very delicate, as the operator’s experience must be used to decide upon
the brush type, the requirement of a possible double scrubbing operation,, the right chemical choice
and the right machine adjustments :if one of these items are inadequate, the scrubbing operation can
give very poor results.
In order to start to scrub is necessary to switch on the brush switch (1), the solenoid valve switch (4)
and the suction switch(2); the scrubbing brushes and the suction motor will start to operate as soon
as the operator pushes the accelerator pedal and after 5 seconds the operator will release the
accelerator pedal both the brushes and vacuum motor stop.
As soon as the scrubbing operation is finished is necessary ,before the suction operation is finished,
to switch off the solenoid valve . f the floor is very dirty or difficult to be cleaned, a double
scrubbing operation is recommended .In this first step ,the squeegee must be lifted up and the
brushes must be in working position. Start the brushes and pass the machine over a surface of some
tenth sq.mt. Let the detergent solution on the floor to dissolve the dirty, then pass the machine
again. For this second machine passage ,lower the brushes and bring the squeegee in contact with
the floor.