background image

        

REVISIONE N°05/001

 

ING. O. FIORENTINI S.p.A. 

INDUSTRIAL CLEANING MACHINES

 

                                                                          ASSEMBLY INSTRUCTIONS                                                                       
 
CONNECTING OF THE CARPET SWEEPER TO THE BRUSH HEAD 
 
Insert the upper part of the carpet sweeper into the brush head, keeping it in vertical position. The knob “1.1” must be 
turned leftwards during this connecting or disconnecting. After the insertion turn the knob in vertical position again. 

FLEXIBLE HOSE CONNECTION 
 
After that the carpet sweeper is insert into the brush head connect the connection “2.1” to the upper carpet sweeper cover. 
The connection “2.2” must be keep in the low part of the upright, reaching the brush head  
joint. 
 

OPERATION/STAND-BY 
 
To start operation, press the block pedal “3.1” and tilt the carpet sweeper backwards, after push on start switch. To stop 
operation, switch off keeping it in vertical position. 

 
Attention: 
Never drive the operating carpet sweeper above its own electric cable. Lift the carpet sweeper when going into stairs or 
high thresholds. 

fig.  3 

 

fig.  2 

fig.  1 

Summary of Contents for GENIUS-14

Page 1: ...REVISIONE N 05 001 ING O FIORENTINI S p A INDUSTRIAL CLEANING MACHINES 0 OPERATOR MANUAL AND PARTS LIST CARPET SWEEPER GENIUS 14 220 Volt ENGLISH USE AND MAINTENANCE MANUAL ...

Page 2: ...ONE N 05 001 ING O FIORENTINI S p A INDUSTRIAL CLEANING MACHINES 1 INDEX page GENERAL SAFETY INSTRUCTIONS 2 ASSEMBLY INSTRUCTIONS 4 MAINTENANCE 6 TECHNICAL DATA 6 TABLE 1 7 TABLE 2 9 TABLE 3 11 ACCESSORIES 13 ...

Page 3: ...erviceable condition or not in compliance with the following prescription is prohibited Protective devices must not be removed or bypassed Conversions and modification to the machine are not permitted Defective supply cables are only to be replaced by original FIORENTINI cables Coupling elements between mains supply or detachable extension cables must be at least splashproof The machine is to be f...

Page 4: ...he connecting plug be withdrawn from the socket Care should be taken to ensure that the connecting cable is not damage by being driven over crushed strained etc The connecting cable should be regularly checked for any signs of damage or ageing The machine must not be used if the connecting cable is not in a proper condition For suction of dry dust check that the filter are in the carpet sweeper Do...

Page 5: ...BLE HOSE CONNECTION After that the carpet sweeper is insert into the brush head connect the connection 2 1 to the upper carpet sweeper cover The connection 2 2 must be keep in the low part of the upright reaching the brush head joint OPERATION STAND BY To start operation press the block pedal 3 1 and tilt the carpet sweeper backwards after push on start switch To stop operation switch off keeping ...

Page 6: ... motor is overloading because the brush height is set too low or there is debris hindering the movement of the brush roller If the overload is excessive circuitry will shut of the brush motor and the red light will stay on until the problem is corrected When the problem is corrected turn the switch off wait for a moment and turn it back on Make sure you unplug the machine while inspecting the brus...

Page 7: ...or is stopped by the electronic unit built in in the carpet sweeper The red light shows this state Remedy Disconnect the carpet sweeper from mains check if the brush is dirty and remove any possible blocking object Restart the carpet sweeper Clogged hose Stop the carpet sweeper remove the hose from the brush head Draw the hose in horizontal position and start the carpet sweeper If the obstruction ...

Page 8: ...REVISIONE N 05 001 ING O FIORENTINI S p A INDUSTRIAL CLEANING MACHINES 7 ...

Page 9: ...R010 1 MANIGLIA SOLLEVAMENTO BATTITAPPETO LIFTING HANDLE POIGNEE DE SOULEVEMEN F35 01 034 VA212 1 VITE AUTOFILET TC 2 9x16 DIN7981 Z SELF THREADING SCREW VIS F35 01 035 IN076 1 MICRO INTER CABL FANT MICRO SWITCH MICRO INTERRUPTEUR F35 01 036 PY559 1 PRESSACAVO PG7 IP54 PA6 CABLE RETAINER PRESSE CABLE F35 01 037 CZ031 1 COPERCHIO SUPERIORE PORTA TURBINA VACUUM MOTOR HOLDER COUVERCLE SUP F35 01 038 ...

Page 10: ...ANIMA ACC D 40 L 560mm FLEXIBLE HOSE TUYAU FLEX F35 01 074 RO909 1 RONDELLA DENTATA D 4 UNI 3706 WASHER RONDELLE F35 01 075 FF019 1 TUBO COLLEGAMENTO PRESS SACCO FAN CONNECTION HOSE PRESS TUYAU F35 01 076 KT050 1 ASSEMBLAGGIO TUBO ASPIRAZIONE COMPLETO COMPLETE WAND ASSEMBLY ASS TUYAU RIGIDE F35 01 077 HH034 1 TUBO RIGIDO INTERNO RIGID WAND TUYAU RIGIDE F35 01 078 MR014 1 COPERTURA MANICO COVER COV...

Page 11: ...REVISIONE N 05 001 ING O FIORENTINI S p A INDUSTRIAL CLEANING MACHINES 10 ...

Page 12: ...350 FANT BRUSH STRIP REFIL BROSSE F35 02 028 VA262 1 VITE AUTOFILET TC 3 5x25 UNI 6954 SELF THREADING SCREW VIS F35 02 029 ML087 1 MOLLA sp filo 0 8mm SPRING RESSORT F35 02 030 LR0308 2 SEEGER BLOCCO RUOTE SEEGER SEEGEER ROUES F35 02 031 LR2012 2 RUOTA PER BATTITAPPETO WHEEL ROUE F35 02 032 RO203 2 RONDELLA NORMALE DIAM 6 UNI 6592 6 WASHER D6 RONDELLE F35 02 033 LR2010 1 MOLLA ASSALE RUOTE WHEELS ...

Page 13: ...REVISIONE N 05 001 ING O FIORENTINI S p A INDUSTRIAL CLEANING MACHINES 12 ...

Page 14: ...MO464 1 MOTORE ASPIRAZIONE 220V VAC MOTOR 230 V MOTEUR ASPIRATION 230 V F35 03 010 CW077 2 CAVETTO MESSA A TERRA MOTORE ASP B GROUNDING CABLE CABLE MISE AU SOL F35 03 011 CW078 1 CAVETTO MICRO SICUREZZA BASAMENTO ELECTRIC CABLE MAMMUT CABLE MICRO DE SURETE F35 03 012 IN057 1 MICRO INTERRUTTORE LUNG 25 MICROSWITCH 25mm MICRO INTERRUPTEUR F35 03 013 CW079 2 CAVETTO MOTORE ASPIRAZIONE ELECTRIC CABLE ...

Page 15: ...ion F35 04 001 HH024 1 TUBO PROLUNGA TUBE EXTENSION RALLONGE F35 04 002 LL007 1 LANCIA PIATTA BATTITAPPETO CREVICE TOOL SUCEUR PLAT F35 04 003 ZZ060 1 PENNELLO BATTITAPPETO ROUND BRUSH BROSSE RONDE F35 04 004 SF040 1 SACCO CARTA PAPER BAG SAC EN PAPIER F35 04 005 SF041 1 10 SACCHI CARTA BATTITAPPETO 10 PAPER BAGS 10 PC SAC PAPIER ...

Page 16: ...t _____________________ Date de spedition ING O FIORENTINI S p A THE BEST IN FLOOR MACHINES FILIALI 20132 MILANO Fax 02 2592779 Via Palmanova 211 a Tel 02 27207783 2564810 00012 Guidonia Montecelio ROMA Fax 0774 353419 353314 Via Ponte Corvo 20 Tel 0774 357184 353015 STABILIMENTO 50030 PIANCALDOLI FI Fax 055 817144 Loc Rombola Tel 055 8173610 Distributed by ...