12
periodically inspected and ch eck ed. Any possible failure, such as detach ed connections and burnt
cables sh ould be im m ediately rem oved.
CAUTION
To clean th e m ach ine, use aggressive detergent solutions, acids, etc. only w h en necessary and
w ith special care. Adh ere to all instructions of th e detergent m anufacturer. Use protective cloth es
(overalls, gloves, protective glasses, etc., see CEE standards).
O PERATIONS ON TH E ELECTR IC INSTALLATION
Th e operations on th e electric installation can be perform ed only by QUALIFIED
ELECTR ICIANS, instructed in th e electric ch aracteristics of th e m ach ine and in accident
prevention rules.
CH ECKS
Th e m ach ine m ust be inspected by a tech nician, w h o ch eck s th e safety conditions of th e m ach ine
and any possible dam ages or defects visible from outside:
- before setting th e m ach ine at w ork
- after appropriate tim e intervals
- after any ch anges or repairs
- safety device control
SAFETY DEVICE CONTR O L
All six m onth , ch eck th e efficiency of th e safety devices, th e inspection sh ould be perform ed by
q ualified personnel of FIO R ENTINI s.r.l. or auth orized by it. To grant th e efficiency of th e
safety devices, th e m ach ine sh ould be overh auled by a tech nician of FIO R ENTINI every 5
m onth s.
ANNUAL CH ECK
Th e responsible person sh ould perform an annual ch eck to determ ine if th e m ach ine com plies
w ith th e tech nical safety standards. After th is ch eck , th e responsible person sh ould apply a test
plate on th e m ach ine.
INFO R M A TION FO R USING TH E MACH INE IN EXPLO SIVE ATM O SPH ERE
Th e m ach ine h as not been designed to w ork in environm ents in w h ich explosive gas, pow ders or
steam s can be generated.
DANGER
To drain th e liq uids used for floor scrubbing, follow th e local standards concerning th e
elim ination and purification.
INFO R M A TION CONCERNING TH E MACH INE DEMOLITION<R> (CEE STANDARDS)
In case of m ach ine dem olition, it is im portant to subdivide th e different types of m aterials
com posing th e m ach ine and deliver th e batteries to operators auth orized to th eir elim ination.
BATTERY TECHNICAL CHARACTERISTICS
BATTERY CAHRGER TECHNICAL CHARACTERISTICS
This kind of battery charter can charge all brand name of batteries.
IN
V 230, Hz 50, A5
OUT
V 24, A 12
TENSION
V 12
CAPACITY
100 A/h
WEIGHT
30 Kg
SIZE (H.x W x.L)
29x17x22.5