4.3.3.10
How to modify the language
Press the button
, then use
or
till the following string
.
Using these buttons
select the desired language and confirm by pressing
:
4.3.3.11
How to modify compartment functions (only for double temperature equipment)
This function allows to exclude one of the two compartments, disabling the alarm signalizations if the chamber is faulty
or not in use.
Press the button
, then use
or
till the following string
.
Once confirmed
, the display will show:
. Using the button
or
, you can
visualise the other probe’s c
ompartment:
.
Confirming with the button
on the wished compartment
(“a” =
upper/left
; “b”=
lower/right), the string
“on”
will start blinking. Use the button
or
to select
“off”, then confirm
. The display will now show a
message asking to confirm or to exit from the Menu with the message:
. Confirm again
with the button
. The display will show message
and it will go back to the main menu.
The following symbol
“*”
next to STATUS OK means that DMLP Digital Monitor has been disabled.
LANGUAGE m10
LINGUA ITALIANA
ENGLISH LANGUAGE
LANGUE FRANCAISE
IDIOMA ESPANOL
DEUTSCHE SPRACHE
MODALITA’
m11
PROBE Sa
on
PROBE Sb
on
<<CONFIRM ESC>>
>> CONFIRMED<<
STATUS OK *