22
WEEKLY OR EVERY 40 HOURS OF OPERATING TIME
1. Clean air cleaner following the instructions in the engine operator’s manual.
2. Lubricate all points on HydroSeeder® as outlined in DAILY in CLEANING AND MAINTE-
NANCE on page 21. Additionally, lubricate the two grease fittings on clutch / pump.
3. Check the oil level in the hydraulic oil reservoir; maintain level with dipstick on filler cap.
4. Inspect slurry tank for buildup of residue in suction area and clear if necessary.
SEASONAL AND WINTER STORAGE MAINTENANCE
1. Drain slurry tank of all water, prior to storage, and remove drain plug.
2. Park unit in suitable location and chock wheels to prevent inadvertent movement.
3. If possible, cover machine with tarp or park inside of an enclosure.
4. Store HydroSeeder® with all slurry valve handles in the open position. To prevent damage
from freezing, it is advisable to remove all slurry valves and store in a heated area.
5. Pour 1 qt (0.95 L) of mineral oil or environmentally safe lubricant into pump housing and
spin pump by hand to prevent rust in pump. Remove drain plug.
6. Chip and steel-brush any interior rust spots in slurry tank and touchup with paint. See
numbers 2 and 3 in IV. Maintenance of the HYDROSEEDER® Safety Summary Section on
page 4.
7. Lubricate all fittings.
8. Lubricate equipment again just prior to putting into operation after having been in storage.
9. Change hydraulic oil and filter. (400 hours)
10. Disconnect battery cables. In cold weather, remove battery and store it in a safe, warm
place.
11. Add fuel stabilizer to fuel tank.