background image

5

Safety

1.    Introduction

 

This manual contains all the information needed for the correct installation, use and maintenance of your new Finish Thompson 

 

pump. It should be read and understood by all the personnel involved in installation, operating and servicing of the pump before  

 

it is started.

2.    Operator Qualification and Training

 

The personnel in charge of the installation, the operation, and the maintenance of the pump must be qualified and able to per- 

 

form the operations described in this manual.  Finish Thompson, Inc. shall not be held responsible for the training level of 

 

personnel and for the fact that they are not fully aware of the contents of this manual.

3.

   

Safety Instructions

 

FOR YOUR OWN SAFETY

 

BEFORE

 using or servicing your pump, please make sure to wear the proper clothing, eye protection and follow standard safety  

 

procedures when handling corrosive or personally harmful materials.

 

ALWAYS

 use and store the pump and motor in an upright position.

  

DANGER: POWER SUPPLY

 

Refer to instructions in the appropriate motor Operation & Installation Manual.

4.  

 

Noise Level

 

Refer to specifications in the appropriate motor Operation & Installation Manual.

5.    Modifications and Spare Parts

 

Any changes concerning the service of the pump as originally purchased can be executed only after written approval from  

 

Finish Thompson Inc.  It is recommended to use only genuine Finish Thompson Inc. spare parts and approved accessories. The  

 

use of non-original spare parts or non-approved accessories will void warranty and removes any responsibility on the manufac- 

 

turer’s behalf for any damage caused to people or things.

6.  

 

Cleaning

 

It is highly recommended to flush pumps with clean water or some other neutralizing fluid compatible with pump materials 

       when done pumping or when switching chemicals.  
                

      re-lubricate the pump internals & rotor after cleaning.

ALWAYS

Summary of Contents for HVDP Series

Page 1: ...1 HVDP SERIES PUMPS OPERATION INSTALLATION PARTS MANUAL ...

Page 2: ...d This declaration is valid provided that the devices are fully assembled and no modifications are made to these devices Type of Device Drum and Container Pump Tubes Models EU Directives Machinery Safety 2006 42 EC Applied Harmonized Standards EN ISO 12100 EN 809 Manufacturer Finish Thompson Inc 921 Greengarden Road Erie Pennsylvania 16501 1591 U S A Signed _ President 1 August 2016 Person s Autho...

Page 3: ...ase reply to our Technical Service department directly at the following address Finish Thompson Inc 921 Greengarden Rd Erie PA 16501 U S A Tel 1 814 455 4478 Fax 1 814 455 8518 www finishthompson com fti finishthompson com Index Introduction 3 Warranty General Terms Conditions 4 Safety 5 Important Safety Information for Pumping Flammable or Hazardous Substances 6 HVDP Terminology 7 HVDP Series Ass...

Page 4: ...sembling with new or repaired parts free of charge delivered by Finish Thompson Inc Parts subjected to normal wear and tear shall not be covered by the warranty Finish Thompson Inc shall decide as to whether the defective or faulty part shall be replaced or repaired Transportation charges are prepaid to Finish Thompson 4 The warranty of the products shall be valid for a period of 12 months from th...

Page 5: ...d safety procedures when handling corrosive or personally harmful materials ALWAYS use and store the pump and motor in an upright position DANGER POWER SUPPLY Refer to instructions in the appropriate motor Operation Installation Manual 4 Noise Level Refer to specifications in the appropriate motor Operation Installation Manual 5 Modifications and Spare Parts Any changes concerning the service of t...

Page 6: ... dommages matéri els ou corporels causés par une utilisation inappropriée de l équipement AVERTISSEMENT Il est de la responsabilité de l utilisateur de faire fonctionner la pompe conformément aux règles OSHA Santé et Sécurité au Travail relatives à la distribution de liquides Les conteneurs de pompes doivent être électriquement mis à la terre lors de l utilisation de liquides inflammables ou combu...

Page 7: ...7 HVDP TERMINOLOGY ...

Page 8: ...STALLATION HVDP LR Figure 1 INSTALLATION HVDP HR 1 Locate the rubber coupling insert that was separately shipped in a plastic bag see Figure 1 2 Install the rubber coupling insert onto the metal coupling half located on top of the HR drive assembly 3 Find the metal coupling half located inside the HR motor Align this coupling with rubber insert installed in the second step of these instructions 4 ...

Page 9: ...ee section 2 3 Remove the bail wire see Figure 3 4 Release the cam lock by pulling the cam lock levers towards the top of the drive assembly 5 Pull the drive assembly out of the pump tube assembly while holding the cam lock levers in the upright position INSTALLATION 1 Make sure that the locating stud on the back of the pump tube assembly is aligned with the drive assembly coupling 2 Push the driv...

Page 10: ...gearbox and the drive shaft see Figure 6 5 Secure the pump drive coupling using a pair of pliers 6 Using a 3 4 open end wrench separate the drive shaft from the gearbox 7 Being sure to protect the polished seal seating area of the shaft gently remove the rotat ing seal boot spring and spring retainer 8 Using a thin bladed screwdriver remove the stationary component of the seal from the gearbox ass...

Page 11: ...105009 1 6 HVDP Rotor 2 105009 2 6 HVDP Rotor 3 105009 3 7 Coupling O ring FKM 105083 7 Coupling O ring EPDM 105084 7 Coupling O ring Buna FDA 108071 7 Coupling O ring PTFE Encapsulated Silicone 105085 ITEM DESCRIPTION PART NO 8 Adapter 1 1 2 105176 8 HVDP Barbed Hose Adpater 2 105287 8 HVDP Tri Clamp Discharge Fitting 107395 9 Union Nut 105023 10 Discharge O ring FKM 107784 10 Discharge O ring EP...

Page 12: ...9 2 5 HVDP Rotor 3 105009 3 6 Coupling O ring FKM 105083 6 Coupling O ring EPDM 105084 6 Coupling O ring Buna FDA 108071 6 Coupling O ring PTFE Encapsulated Silicone 105085 ITEM DESCRIPTION PART NO 7 HVDP Barbed Hose Adapter 1 1 2 105176 7 HVDP Barbed Hose Adapter 2 105287 7 HVDP Tri Clamp Discharge Fitting 107395 8 Union Nut 105023 9 Discharge O ring FKM 107784 9 Discharge O ring EPDM 107785 9 Di...