background image

2

 

 

 

 

EU Declaration of Conformity

 

 

 

 

 

 

 

Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the 

applicable health and safety requirements as specified by the EU Directives listed. The product may 

not be taken into service until it has been established that the drive motor for the Drum and 

Container Pump complies with the provisions of all relevant EU Directives. The complete product 

complies with the provisions of the EU Directive on machinery safety provided motors 

manufactured by Finish Thompson Inc. are used.  

 

This declaration is valid provided that the devices are fully assembled and no modifications are 

made to these devices. 

 

Type of Device:

 

Drum and Container Pump Tubes 

 

Models:

 

 

EU Directives:

 

Machinery Safety (2006/42/EC) 

 

Applied Harmonized Standards:

 

EN ISO 12100 

EN 809 

 

Manufacturer: Finish 

Thompson Inc. 

921 Greengarden Road 

Erie, Pennsylvania 16501-1591 U.S.A

 

 

Signed, 

 

 

  

President 

 

1 August 2016 

 

Person(s) Authorized to Compile Technical File:  Finish Thompson GmbH 

     Otto-Hahn-Strasse 16 

     Maintal, D-63477 DEU 

     Telephone:  49 (0)6181-90878-0 

BTS – 40 

EPPI/EPPS 15/27/40 

EFP/EFV/EFS-16/27/40/48/54 

HVDP LR-27/40/48 

HVDP HR-27/40/28 

PFM-27/40/48/60 

PFP-15/27/40/48/60/72 

PFS-27/40/48/60/72 

PFV-27/40/48/60/72 

TBP-27/40/48 

TBS-40 

TTC/TTS-27/40/48 

STTS-40 

TMS-40 

 

Summary of Contents for HVDP Series

Page 1: ...1 HVDP SERIES PUMPS OPERATION INSTALLATION PARTS MANUAL ...

Page 2: ...d This declaration is valid provided that the devices are fully assembled and no modifications are made to these devices Type of Device Drum and Container Pump Tubes Models EU Directives Machinery Safety 2006 42 EC Applied Harmonized Standards EN ISO 12100 EN 809 Manufacturer Finish Thompson Inc 921 Greengarden Road Erie Pennsylvania 16501 1591 U S A Signed _ President 1 August 2016 Person s Autho...

Page 3: ...ase reply to our Technical Service department directly at the following address Finish Thompson Inc 921 Greengarden Rd Erie PA 16501 U S A Tel 1 814 455 4478 Fax 1 814 455 8518 www finishthompson com fti finishthompson com Index Introduction 3 Warranty General Terms Conditions 4 Safety 5 Important Safety Information for Pumping Flammable or Hazardous Substances 6 HVDP Terminology 7 HVDP Series Ass...

Page 4: ...sembling with new or repaired parts free of charge delivered by Finish Thompson Inc Parts subjected to normal wear and tear shall not be covered by the warranty Finish Thompson Inc shall decide as to whether the defective or faulty part shall be replaced or repaired Transportation charges are prepaid to Finish Thompson 4 The warranty of the products shall be valid for a period of 12 months from th...

Page 5: ...d safety procedures when handling corrosive or personally harmful materials ALWAYS use and store the pump and motor in an upright position DANGER POWER SUPPLY Refer to instructions in the appropriate motor Operation Installation Manual 4 Noise Level Refer to specifications in the appropriate motor Operation Installation Manual 5 Modifications and Spare Parts Any changes concerning the service of t...

Page 6: ... dommages matéri els ou corporels causés par une utilisation inappropriée de l équipement AVERTISSEMENT Il est de la responsabilité de l utilisateur de faire fonctionner la pompe conformément aux règles OSHA Santé et Sécurité au Travail relatives à la distribution de liquides Les conteneurs de pompes doivent être électriquement mis à la terre lors de l utilisation de liquides inflammables ou combu...

Page 7: ...7 HVDP TERMINOLOGY ...

Page 8: ...STALLATION HVDP LR Figure 1 INSTALLATION HVDP HR 1 Locate the rubber coupling insert that was separately shipped in a plastic bag see Figure 1 2 Install the rubber coupling insert onto the metal coupling half located on top of the HR drive assembly 3 Find the metal coupling half located inside the HR motor Align this coupling with rubber insert installed in the second step of these instructions 4 ...

Page 9: ...ee section 2 3 Remove the bail wire see Figure 3 4 Release the cam lock by pulling the cam lock levers towards the top of the drive assembly 5 Pull the drive assembly out of the pump tube assembly while holding the cam lock levers in the upright position INSTALLATION 1 Make sure that the locating stud on the back of the pump tube assembly is aligned with the drive assembly coupling 2 Push the driv...

Page 10: ...gearbox and the drive shaft see Figure 6 5 Secure the pump drive coupling using a pair of pliers 6 Using a 3 4 open end wrench separate the drive shaft from the gearbox 7 Being sure to protect the polished seal seating area of the shaft gently remove the rotat ing seal boot spring and spring retainer 8 Using a thin bladed screwdriver remove the stationary component of the seal from the gearbox ass...

Page 11: ...105009 1 6 HVDP Rotor 2 105009 2 6 HVDP Rotor 3 105009 3 7 Coupling O ring FKM 105083 7 Coupling O ring EPDM 105084 7 Coupling O ring Buna FDA 108071 7 Coupling O ring PTFE Encapsulated Silicone 105085 ITEM DESCRIPTION PART NO 8 Adapter 1 1 2 105176 8 HVDP Barbed Hose Adpater 2 105287 8 HVDP Tri Clamp Discharge Fitting 107395 9 Union Nut 105023 10 Discharge O ring FKM 107784 10 Discharge O ring EP...

Page 12: ...9 2 5 HVDP Rotor 3 105009 3 6 Coupling O ring FKM 105083 6 Coupling O ring EPDM 105084 6 Coupling O ring Buna FDA 108071 6 Coupling O ring PTFE Encapsulated Silicone 105085 ITEM DESCRIPTION PART NO 7 HVDP Barbed Hose Adapter 1 1 2 105176 7 HVDP Barbed Hose Adapter 2 105287 7 HVDP Tri Clamp Discharge Fitting 107395 8 Union Nut 105023 9 Discharge O ring FKM 107784 9 Discharge O ring EPDM 107785 9 Di...