![Fini MEGA SD 50 Instruction And Maintenance Manual Download Page 19](http://html.mh-extra.com/html/fini/mega-sd-50/mega-sd-50_instruction-and-maintenance-manual_2289772019.webp)
MENU A
1
MEGA SD - Cod.197DD8100
GB
START-Up AND OpERATION
4.1 ADDITIONAL INFOrMATION MENU
Indicates the maximum operating pressure of the compressor
(ref. paragraph 4.2.5)
Indicates the minimum operating pressure of the compressor
(ref. paragraph 4.2.5)
Indicates operating mode setting:AuTOMATIC / CONTIN.
(ref. paragraph 4.2.3)
Indicates setting of the type of control: LOCAL/ REMOTE/
PROGRAM (ref. paragraph 4.2.3)
if enabled, indicates the status of the AuTORESTART function
(automatic restart following blackout) (ref. paragraph 4.2.3)
Only if the CAN-buS communication module has been
Installed
Indicates the order in which the machines are started (ref.
paragraph 4.2.4.)
Indicates the total hours of operation of the compressor (ref.
paragraph 4.2.2)
Indicates the total hours of operation of the compressor at full
load (ref. paragraph 4.2.2)
Indicates the time remaining to initial maintenance: any other
maintenance operations to be carried out within 100 hours from
initial maintenance are also displayed cyclically (ref. paragraph
4.2.2.)
It provides the information consulted most frequently and is
Pressure XX,X bar (psi
Temperature XXX °C(°F)
ready for start
10:40 MON 25/05/2011
MAIN SCrEEN PAGE
Operating press.
Max:
8.0 bar
Operating press.
Min:
6.5 bar
Operating mode
State: AuTOMATIC
Type of control
Control: LOCAL
AuTORESTART function State
State:
OFF
ID compressor
N° station: 1
Net sequence
ID
4-3-1-2
Operating time
Total: XXXX ore.
Operating time
On load: XXXX ore
Time to service:
oil: XXXX ore
shown below.