Fineco Electric EM737 User Manual Download Page 8

 

                                                                                                                                                                                       

User Manual EM737   

                                                                                                                                                                                                                              Document code: Fineco737-1-1.1 Revision2.003   

Shanghai fangqiu electric CO.,LTD.                                                                                                                                                      Email: 

[email protected]

 

                                                                                                                                                                                                                                           

27 

Active energy import 

0800/0160 

28 

Active energy export 

0900/0166 

29 

Reactive energy import 

0A00/0162 

30 

Reactive Energy export 

0B00/0168 

 
Production data and identification 

No 

Comments 

Read 

Write  Bytes  Starting address 

31 

Serial number 

FF00 

32 

Manufacture code 

FF02 

33 

Type code 

FF04 

34 

Hardware version 

FF05 

35 

Software version 

FF06 

 
Settings 

No 

Comments 

Read  Write 

Bytes  Starting address 

36 

Modbus id 

0524 

37 

Baud rate 

0525 

Lcd content   

 

 

 

 

Description of LCD symbols displayed 

    Symbol 

Description 

 

kWh—active energy        kW—active power     
kvarh—reactive energy        kvar—reactive power 
kVA—apparent power 

 

Total   

 

Unpermitted programming   

 

LCD alarm indicator

 

 

Communication symbols 

 

 

8.3

 Electricity parameters measurement and monitoring

 

Electrical measurements:   
              Volts                                                          L1,L2,L3-N 
              Amps                                                          L1,L2,L3,

Σ

,Neutral 

              kW&kvar&kVA&PF                                    L1,L2,L3,

Σ

 

              Frequency 
              kWh,kvarh                                                  +, -, 

Σ

 

              kW& kvar Demand                                      +, -, 

Σ

 

  Also can display the direction of the current and power. The resolution of frequency is 

0.01Hz. the accuracy of Voltage, current, active power,reactive power and apparent power is 

1%. 

kVVArh

Summary of Contents for EM737

Page 1: ...o EN50470 3 LCD display 6 integer 2 decimal Large clear back light display Electrical measurements Volts L1 L2 L3 N Amps L1 L2 L3 Neutral kW kvar kVA PF L1 L2 L3 Frequency kWh kvarh kW kvar Demand Iso...

Page 2: ...chnical description 5 1 Performance criteria 5 2 Meter specification 5 3 Dimensions and sealing points 6 Wiring diagrams 7 Meter reading 8 Main function 8 1 Measuring Function 8 2 Display function 8 3...

Page 3: ...tarting meter operation it must be ensured the local conditions of the energy system are consistent with data on the nameplate of the meter Preferably use for the connection of shielded cables Make su...

Page 4: ...storage temperature 25 C 55 C 1K4 Humanity 75 yearly average 95 on 30 days year International standard EN50470 3 IEC62053 21 Accuracy class Class B Protection against penetration of dust and water IP5...

Page 5: ...circuits VA 0 01 Power consumption of voltage circuits W 1 3W General data Frequency Hz 50 Memory back up EEprom Environment resistance to heat and fire Terminal 960 Cover 650 upper ABS PC lower ABS...

Page 6: ...ulse output and the communication interface RS 485 However depending on the ordering number of the energy meter only some terminals of the energy meters are involved 1 2 L1 in out 3 4 L2 in out 5 6 L3...

Page 7: ...1 Voltage L1 Y N 4 0010 2 Voltage L2 Y N 4 0012 3 Voltage L3 Y N 4 0014 4 Current L1 Y N 4 0016 0050 5 Current L2 Y N 4 0018 0052 6 Current L3 Y N 4 001A 0054 7 Current N Y N 4 001C 0056 8 Total curre...

Page 8: ...2 FF06 Settings No Comments Read Write Bytes Starting address 36 Modbus id Y Y 2 0524 37 Baud rate Y Y 2 0525 Lcd content Description of LCD symbols displayed Symbol Description kWh active energy kW...

Page 9: ...ances with communication equipment and Energy meters to preventing signal reflection and interference 3 Communication circuit should keep distance with Large current circuit and shall not be parallel...

Page 10: ...he Password Password to default 8888 9 2 ID setting After the Password authentication the meter will display the ID XX setup interface As the following picture Id 00 it means the current ID address is...

Page 11: ...the password Use page down and page up button to input password as you want After 30 seconds the meter will save the password you changed Remarks 1 Do not forget the password you setup 2 Please press...

Reviews: