Power consumption of 
current circuits(VA) 

< 0.01 

Power consumption of 
voltage circuits(W) 

< 1.3W 

General data 
Frequency (Hz) 

50 

Memory back-up 

EEprom 

Environment resistance to 
heat and fire 

Terminal 960

 

Cover 650

 

upper 

ABS+PC 

lower 

ABS+PC 

Pulse output 

 

Pulse width(ms) 

80 

Pulse constant(imp/kWh) 

400 

LED constant 

400 

Width (mm) 

126 

Height (mm) 

104.5 

Depth (mm) 

60 

 

5.3

 

Dimensions and sealing points

 

 

 

 
 

Summary of Contents for EM737

Page 1: ...o EN50470 3 LCD display 6 integer 2 decimal Large clear back light display Electrical measurements Volts L1 L2 L3 N Amps L1 L2 L3 Neutral kW kvar kVA PF L1 L2 L3 Frequency kWh kvarh kW kvar Demand Iso...

Page 2: ...chnical description 5 1 Performance criteria 5 2 Meter specification 5 3 Dimensions and sealing points 6 Wiring diagrams 7 Meter reading 8 Main function 8 1 Measuring Function 8 2 Display function 8 3...

Page 3: ...tarting meter operation it must be ensured the local conditions of the energy system are consistent with data on the nameplate of the meter Preferably use for the connection of shielded cables Make su...

Page 4: ...storage temperature 25 C 55 C 1K4 Humanity 75 yearly average 95 on 30 days year International standard EN50470 3 IEC62053 21 Accuracy class Class B Protection against penetration of dust and water IP5...

Page 5: ...circuits VA 0 01 Power consumption of voltage circuits W 1 3W General data Frequency Hz 50 Memory back up EEprom Environment resistance to heat and fire Terminal 960 Cover 650 upper ABS PC lower ABS...

Page 6: ...ulse output and the communication interface RS 485 However depending on the ordering number of the energy meter only some terminals of the energy meters are involved 1 2 L1 in out 3 4 L2 in out 5 6 L3...

Page 7: ...1 Voltage L1 Y N 4 0010 2 Voltage L2 Y N 4 0012 3 Voltage L3 Y N 4 0014 4 Current L1 Y N 4 0016 0050 5 Current L2 Y N 4 0018 0052 6 Current L3 Y N 4 001A 0054 7 Current N Y N 4 001C 0056 8 Total curre...

Page 8: ...2 FF06 Settings No Comments Read Write Bytes Starting address 36 Modbus id Y Y 2 0524 37 Baud rate Y Y 2 0525 Lcd content Description of LCD symbols displayed Symbol Description kWh active energy kW...

Page 9: ...ances with communication equipment and Energy meters to preventing signal reflection and interference 3 Communication circuit should keep distance with Large current circuit and shall not be parallel...

Page 10: ...he Password Password to default 8888 9 2 ID setting After the Password authentication the meter will display the ID XX setup interface As the following picture Id 00 it means the current ID address is...

Page 11: ...the password Use page down and page up button to input password as you want After 30 seconds the meter will save the password you changed Remarks 1 Do not forget the password you setup 2 Please press...

Reviews: