User Manual EM737
Document code: Fineco737-1-1.1 Revision2.003
Shanghai fangqiu electric CO.,LTD. Email:
9 Programming
By holding the keys “SET” pressed for at last 3 sec., starts menu programming
mode.LCD will show:
9.1 password verify
On the smart meter display will appear : PA followed by the currently memorized
value . “PA” means “Password”,”0000”means the 4 digits of the Password. we can use
press “Page Down” button to decrease the input value, and press “Page Up” to increase
the input value ,press the “SET” button to switch the input Password digits, when the
Password is correct, the meter will enter “program status” and display the “ID” program
interface.
Remarks:
Please remember well the Password, Password to default (8888).
9.2 ID setting
After the Password authentication , the meter will display the “ID XX” setup
interface. As the following picture ”Id 00” it means the current ID address is 00 (the ID
address is hex code)
Press “Page Down” button to decrease the digits. press ”Page Up” to increase the
digits
,
press “SET” button to save the setup, the interface will switch to Baud rate setup
interface automatically. Press “SET” button to enter next interface if you do not need to
change the baud rate.
9.3 Baud rate setting
we can use press “Page Down” button to decrease the input value, and press “Page
Up” to increase the input value ,press the “SET” button to switch the input digits, when
the baud rate is correct, the meter will enter “program status” and display the “CT”
program interface.
Remarks
:
1.
Default baud rate will be 9600bps
2.
1200/2400bps /4800bps/9600bps can be set
9.3 Password setting
: