Fineco Electric EM737 User Manual Download Page 1

 

                                                                                                                                                                                       

User Manual EM737   

                                                                                                                                                                                                                              Document code: Fineco737-1-1.1 Revision2.003   

Shanghai fangqiu electric CO.,LTD.                                                                                                                                                      Email: 

[email protected]

 

                                                                                                                                                                                                                                           

User    Manual 
Revision    2.003 
English 
 

Smart energy meter 

EM737    0.5-10(100)A 

 

 

 
 

Shanghai fangqiu electric CO.,LTD. 

 
 

Benefits and Main Features 

 

MID approved with appendix "B" and "D" certification 

 

Three phase metering ,7 DIN modules 

 

Direct metering up to 100A 

 

Accuracy class B according to EN50470-3   

 

LCD display, 6 integer 2 decimal 

 

Large clear back light display 

 

Electrical measurements:   

              Volts                                                          L1,L2,L3-N 
              Amps                                                          L1,L2,L3,

Σ

,Neutral 

              kW&kvar&kVA&PF                                    L1,L2,L3,

Σ

 

              Frequency 
              kWh,kvarh                                                  +, -, 

Σ

 

              kW& kvar Demand                                      +, -, 

Σ

             

 

Isolate pulse output and IR (DIN43864) 

 

Optional single-phase model 

 

RS485 communication port, modbus protocol 

 

IR port   

 

Program by button on the nameplate 

 

Memory back-up (EEprom) 

 

The meter is intended to be installed in a Mechanical Environment ‘M1’, with Shock 
and Vibrations of low significance, as per 2004/22/EC Directive and should be installed 
in Electromagnetic Environment ‘E2’, as per 2004/22/EC Directive. 
 
 

Summary of Contents for EM737

Page 1: ...o EN50470 3 LCD display 6 integer 2 decimal Large clear back light display Electrical measurements Volts L1 L2 L3 N Amps L1 L2 L3 Neutral kW kvar kVA PF L1 L2 L3 Frequency kWh kvarh kW kvar Demand Iso...

Page 2: ...chnical description 5 1 Performance criteria 5 2 Meter specification 5 3 Dimensions and sealing points 6 Wiring diagrams 7 Meter reading 8 Main function 8 1 Measuring Function 8 2 Display function 8 3...

Page 3: ...tarting meter operation it must be ensured the local conditions of the energy system are consistent with data on the nameplate of the meter Preferably use for the connection of shielded cables Make su...

Page 4: ...storage temperature 25 C 55 C 1K4 Humanity 75 yearly average 95 on 30 days year International standard EN50470 3 IEC62053 21 Accuracy class Class B Protection against penetration of dust and water IP5...

Page 5: ...circuits VA 0 01 Power consumption of voltage circuits W 1 3W General data Frequency Hz 50 Memory back up EEprom Environment resistance to heat and fire Terminal 960 Cover 650 upper ABS PC lower ABS...

Page 6: ...ulse output and the communication interface RS 485 However depending on the ordering number of the energy meter only some terminals of the energy meters are involved 1 2 L1 in out 3 4 L2 in out 5 6 L3...

Page 7: ...1 Voltage L1 Y N 4 0010 2 Voltage L2 Y N 4 0012 3 Voltage L3 Y N 4 0014 4 Current L1 Y N 4 0016 0050 5 Current L2 Y N 4 0018 0052 6 Current L3 Y N 4 001A 0054 7 Current N Y N 4 001C 0056 8 Total curre...

Page 8: ...2 FF06 Settings No Comments Read Write Bytes Starting address 36 Modbus id Y Y 2 0524 37 Baud rate Y Y 2 0525 Lcd content Description of LCD symbols displayed Symbol Description kWh active energy kW...

Page 9: ...ances with communication equipment and Energy meters to preventing signal reflection and interference 3 Communication circuit should keep distance with Large current circuit and shall not be parallel...

Page 10: ...he Password Password to default 8888 9 2 ID setting After the Password authentication the meter will display the ID XX setup interface As the following picture Id 00 it means the current ID address is...

Page 11: ...the password Use page down and page up button to input password as you want After 30 seconds the meter will save the password you changed Remarks 1 Do not forget the password you setup 2 Please press...