background image

http:// en.fineart-light.com 

- 7 - 

Lamp 

Lamp model: HTI 700W/D4/75 

Fine700 Spot use OSRAM HTI 700 W/D4/75 discharge lamp, as this 

efficient short-arc source with a color temperature of 7380 K, a color 
rendering index of 75, an average service life of 750 hours and hot restrike. 

Warning! Install other lamps will creates safety hazard or damage the 

fixture. 

The average service life of this lamp is 750 hours, in order to reduce 

the risk of fixture, please replace the lamp before the usage exceed 125% of 
the service life. 

Lamp replacement 

Note! Don’t touch the bulb with bare hands, so oils won’t touch the 

bulb, keep the bulb clean. Clean lamp with alcohol, and polish it with dry 
cloth. 

Operation of Lamp replacement 

1.    Cut off the power supply, cool off it at least 30 minutes, place the body 

at 15, and lock the body.   

2.    See picture 2, open the cover, loose the screws as the arrow showed, 

pull the lamp assembly straight back as far as it goes and let it rest in 
place. 

                                                                   

Picture

 2 

3.    See picture 3, To disassembly the lamp, loose the poles of the lamp with 

a screwdriver from the socket, then pull out two poles one by one 
respectively. 

Picture

 3 

http:// en.fineart-light.com 

- 8 - 

4.  See picture 4, To install the lamp, Aim two poles of the lamp to the 

matched socket in advance (Ensure the direction of  lamp’s nipple 
toward the socket), then push two poles into the socket synchronously. 

                                                      Picture4 

5.  Lift the lamp assembly so that lamp is level with the center of the 

reflector. Push the assembly straight in until it seats, making sure the 
lamp passes   

Note: Push and pull the lamp assembly along with the slider bar, don’t touch 

hardware that locate around the reflector, in case the lamp broken.   

 

To align the lamp 

1.   Apply power and allow the fixture to reset. Using a controller or the 

control menu, strike the lamp and project an open white beam on a flat 
surface. 

2.  See Figure 5. Center the hot spot vertically using the top Allen-head 

adjustment screw (A) in the center of the rear plate. Center the hot spot 
horizontally using the side-to-side adjustment screws (B).   

3.    If there is an excessive hot spot, turn the bottom adjustment screw (B) 

counterclockwise until the light is evenly distributed. If the light is 
brighter around the edge than it is in the center, or if light output is low, 
turn the bottom adjustment screw (B) clockwise until the light is bright 
and evenly distributed.   

4.  Repeat Step 2. 

Summary of Contents for FINE700

Page 1: ...DMX Data Connection 10 Installation 11 Install Fixtures on Truss 11 Control Panel 13 DMX Address and protocol 13 Fine 700 Spot Gobo Color configuration 13 Animation Wheel 13 Gobo Wheel 14 Color Wheel...

Page 2: ...lethal or severe injury due to fire and heat electric shock ultraviolet radiation lamp explosion and falls Read this manual before powering or installing the fixture follow the safety precautions list...

Page 3: ...eters around fans and air vents z Don t place filters or other materials over the lens z Cool off the fixture at lease 30 minutes before removing it z Use the spares which are from FINE ART z Don t op...

Page 4: ...two poles one by one respectively Picture 3 http en fineart light com 8 4 See picture 4 To install the lamp Aim two poles of the lamp to the matched socket in advance Ensure the direction of lamp s n...

Page 5: ...tor Marks Brown Live wire L Blue Neutral wire N Yellow Green Ground wore Data Important Never connect more than 1 data input and 1 data output FINE700 Spot has both 3 pin and 5 pin XLR sockets for DMX...

Page 6: ...can bear at least 10 times the weight of the fixture Check that the structure can bear at least 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc http en fineart ligh...

Page 7: ...animation wheel with the magnet in towards the drive mechanism for a more secure hold Remove the gobo module as described on page 31 Routine maintenance Disassembly http en fineart light com 14 Bring...

Page 8: ...he gobo out of the holder 3 Insert the new gobo in the holder insert the spring with the narrow end against the gobo and push the end of the spring in under the lip of the holder 4 Work the rim of the...

Page 9: ...gobos There are 6 gobos on the rotating gobo wheel Gobos can rotate with different speed or index in a position and with 16 bit fine resolution Gobos can be selected indexed positioned at a programme...

Page 10: ...nnel 10 Gobo II Channel 11 Gobo color Macro function Channel 12 animation wheel Channel 13 animation wheel angle speed Channel Prism Channel 15 Iris Channel 16 Focus Channel 17 Zoom Channel 18 Pan Cha...

Page 11: ...fast Random opening pulse slow Random closing pulse fast Random closing pulse slow Shutter open Reset fixture Shutter open Lamp on Shutter open lamp off 2 2 0 255 0 100 Dimmer 0 100 http en fineart li...

Page 12: ...102 color 1 green 208 open 10 6 199 219 220 240 241 245 246 250 251 255 78 86 86 94 95 96 96 98 98 100 continuous rotation of colors clockwise fast slow anticlockwise slow fast random position and col...

Page 13: ...eel I 16bit 15 10 0 11 11 22 22 33 33 44 44 55 55 66 66 77 0 4 4 8 8 13 13 17 17 21 21 26 26 30 gobo wheel II smooth change of colors white gobo1 gobo1 2 gobo2 3 gobo3 4 gobo4 5 gobo5 6 gobo6 7 http e...

Page 14: ...iclockwise slow fast clockwise fast slow no rotation http en fineart light com 28 19 14 0 19 20 79 80 89 90 149 150 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 0 7 8 31 31 35 3...

Page 15: ...it tracking mode color switch during the movement http en fineart light com 30 31 23 0 245 246 248 249 251 252 255 0 2 3 245 246 251 252 255 0 251 252 245 0 96 96 97 98 98 99 100 0 1 1 96 96 98 99 100...

Page 16: ...Y smooth adjustment Channel Channel 01 0 255 shutter on off strobe qui ck resetlighter Channel 02 0 255 0 100 dimmer Channel 03 0 255 CMY Cyan http en fineart light com 32 Channel 04 0 255 CMY Magenta...

Page 17: ...com 34 Adjust Slot 00 0000 FFFF dimmer excursion Slot 01 0000 FFFF magenta excursion Slot 02 0000 FFFF iris excursion Slot 03 0000 FFFF zoom excursion Slot 04 0000 FFFF rotation of animation wheel ex...

Page 18: ...ht com 36 Code 5 Code 6 Code 7 Code 8 Code 9 Code 11 Code 12 Code 13 Code 14 Code 15 Reset Home Manual reset of fixture Reset Routine Maintenance FINE700 series products require routine maintenance Th...

Page 19: ...h to the top position which is near the light head http en fineart light com 38 Picture 16 4 See picture 17 Turn the fixture to the proper position pull the strap in the direction shown in the picture...

Page 20: ...tely and then remove the cover 2 Vacuum or gently blow away dust and loose particles with compressed air 3 Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner o...

Page 21: ...Position the filters on the side covers and reinstall it Picture 21 http en fineart light com 42 Fine 700 Spot Channel Protocol 8 20 2 18 SIGNAL INPUT 23 fan 16 13 fan fan 29 26 27 14 17 1 1 1 1 15 L...

Reviews: