background image

Page 4 

 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free 

of any foreign material. Rinse tank out of any tank residue before filling 

with water to test. 

 

Testing the Sprayer 

NOTE: 

CHECK and TEST the completed sprayer with plain water. This will enable you 

to check the sprayer for leaks without the possibility of losing any expensive 

chemicals. 

 

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will 

start solution spraying from the tips of the boom. The pressure will decrease slightly when 

the boom is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail 

B). Make sure your pattern is sufficient. You may down-pressure the system by 

‘bypassing’ solution back into the tank. This is achieved by opening the bypass valve. 

Regulating pressure is done in this manner. 

 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Ad-

just’ valve and opening the boom line valve (Detail A). This will enable the air in the line to 

be eliminated (purged) through all the tips, while building pressure. When everything tests 

all right (no leaks and good pressure), add the desired chemicals to the mixture and water 

combination and start your spraying operation. Adjust the pressure and spray as you did 

in the testing procedure. 

 

Conditions of weather and terrain must be considered when setting the sprayer. Do not 

spray on windy days. Protective clothing must be worn in some cases 

 

Be sure to read the chemical label(s) before application!

 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. 

The pump forces the solution under pressure to the handgun or boom nozzles. 

 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand-alone 

battery or the battery on your towing vehicle. Connect to the positive (red) terminal first, 

then connect to the negative (black) terminal. Then connect the end of the lead wire to the 

end of the pump. When disconnecting, disconnect the end of the pump wire from the lead 

wire, then disconnect the negative (black) connection and finally the positive (red) con-

nection. The lead wire has an On/Off switch to activate the pump. “-” is on and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of chemical to be 

sprayed. Finish filling tank to proper level. Turn the pump on and by depressing the “-” 

side of the rocker switch. The pump is equipped with a pressure switch that is pre-set at 

the factory to shut the pump off when all discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with either the boom or the handgun, pressure may be reduced by slowly 

opening the bypass valve until desired pressure is achieved (Detail B). Opening the valve 

decreases pressure, closing the valve increases pressure. When spraying with the boom, the proper method to set the pressure is to open the boom 

valve completely and if a lower pressure is desired, then slowly open the bypass valve until that pressure is obtained. 

 

For the safest and most efficient chemical application, you will need to calibrate your sprayer using the tip and speed charts. Once you have deter-

mined the proper speed and pressure settings, you will need to consult your chemical label for the amount of chemical to be added to the tank. Read 

the entire label. Use only according to label directions. 

 

Calibration 

Chemical labels may show application rates in gallons per acre, gallons per 1000 square feet or gallons per 100 square feet. You will note that the tip 

chart shows 3 of these rating systems. Once you know how much you are going to spray, then determine (from the tip chart) the spraying pressure 

(PSI), and the spraying speed (MPH). 

 

Determining the proper speed of the pulling vehicle can be done by marking off 100, 200 & 300 feet. The speed chart indicates the number of seconds 

it takes to travel the distances. Set the throttle and with a running start, travel the distances. Adjust the throttle until you travel the distances in the num-

ber of seconds indicated by the speed chart. Once you have reached the throttle setting needed, mark the throttle location so you can stop and go 

again, returning to the same speed. 

 

Add water and proper amount of chemical to the tank and drive to the starting place for spraying. 

Detail A 

Detail B 

Manifold Valves CLOSED 

Summary of Contents for 5302944

Page 1: ...erating instructions and then run the sprayer using only water for testing When everything tests all right add the desired chemical mixture and water combination and start the spraying operation OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries ...

Page 2: ...e Item 3 against o ring Item 2 and slide both into the nozzle body opening firmly 4 Firmly tighten flynut Item 4 onto threads of nozzle body 5 Repeat for other side NOTE If water is shooting back on the boom tube item 2 is not in the correct placement End Nozzle Information 5275122 This nozzle mounting stem Has a ratcheting motion Each click of the ratcheting motion is approx 15 For proper optimal...

Page 3: ... the manifold The boom hose can be cut to length if needed Once fully assembled to remove the sprayer from a UTV Box disconnect the boom supply hose from the manifold us ing the quick connect fitting Then loosen the two lobe knobs on the tank mounts and slide the boom out and set aside Then the tank can be removed and set on the ground without damaging the tank or boom The handles can be used to l...

Page 4: ...y the positive red con nection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rocker switch The pump is equipped with a pressure switch that is pre set at the factory to shut the pump off when ...

Page 5: ...nd Cleaner If no tank cleaner is available you may substitute dish soap for this step about 1 2 oz per gallon Turn pump on and circulate through system for 15 minutes and then spray out through boom and handgun nozzles Refill sprayer half way with clean water and repeat Follow the chemical manufacturer s disposal instructions of all wash or rinsing water If boom or handgun nozzles need cleaning re...

Page 6: ...r defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge...

Page 7: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Page 8: ...Detail A Exploded View LG 45 BL UTV 5302944 Detail B Detail B Boom Feeder Hose Detail A Refer to the parts list on next page for part numbers Refer to Page 10 for the UTV intake assembly breakdown Reference 9 ...

Page 9: ...Page 9 Parts List LG 45 BL UTV 5302944 Manifold Detail 5278781 Boom Mount 5278715 Strainer 5116417 Boom Tube Assembly Detail Refer to the parts list above for part numbers ...

Page 10: ...enter Nozzle Assembly 5275123 End Nozzle Assembly 5275122 Boomless Wet Boom Assembly Exploded View Parts List 5275260 Intake Detail UTV Intake Plumbing 5278928 Refer to the parts list on page 9 for part numbers ...

Page 11: ...se the pressure adjustment control on the manifold to recirculate the mixture through tank Properly secure the tank to your utility vehicle using tie down or ratchet straps Not Included Tank straps may be installed through the handles to help prevent straps from slipping off tank if too loose Handles can be used to lift the empty tank in and out of the box Stay within your utility vehicle s weight...

Page 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: