background image

Page 6 

 

Speed Chart 

  

Time Required in seconds 

Speed in M.P.H. 
(Miles Per Hour) 

100 Ft. 

200 Ft. 

300 Ft. 

1.0 

68 sec. 

136 sec.  

205 sec. 

2.0 

34 

68 

102 

3.0 

23 

45 

68 

4.0 

17 

34 

51 

5.0 

14 

27 

41 

6.0 

11 

23 

34 

7.0 

9.7 

19 

29 

8.0 

8.5 

17 

26 

9.0 

7.6 

15 

23 

10.0 

6.8 

14 

20 

Using the Boom Nozzles 

Four things must be considered before spraying with the boom. 

 

How much chemical must be mixed in the tank. 

 

Rate of spray (gallons per acre to be sprayed). 

 

What pressure (p.s.i.) will be used. 

 

Speed traveled (mph) while spraying. 

 

Refer to the chemical label to determine your chemical mixture 

 

See the tip chart to determine the pressure to be used. The chart will also show the speed used when spraying. 

 

Start the pump and open the valve to the boom nozzles. 

 

Check the spray pattern. Usually you can see the coverage better on a solid concrete surface, such as a driveway. 

 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake line. 

 

Proper care and maintenance will prolong the life of your sprayer. 

 

 

 

 

 

 

After use, drain the tank and store or dispose of chemical properly. Fill the sprayer half way with clean water. Start the pump and allow the water to 

pump through the entire plumbing system and nozzles. Drain and then refill half full, add the recommended amount of a good quality tank cleaner, 

such as FIMCO Tank Neutralizer and Cleaner. (If no tank cleaner is available, you may substitute dish soap for this step, about 1-2 oz. per gallon).  

Turn pump on and circulate through system for 15 minutes and then spray out through boom and handgun nozzles. Refill sprayer half way with clean 

water and repeat. Follow the chemical manufacturer’s disposal instructions of all wash or rinsing water.  

If boom or handgun nozzles need cleaning, remove them from the sprayer and soak in warm soapy water. Clean with a soft bristled brush or toothpick 

if necessary. Never use a metal object. Even the slightest damage can change the flow rate and spray distribution. Water rinse and dry the tips before 

storing. 

 

WARNING: 

Some chemicals will damage the pump valves if allowed to soak untreated for a length of time! ALWAYS flush the pump as 

instructed after each  use. DO NOT allow chemicals to sit in the pump for extended times of idleness. Follow the chemical manufacturer’s 

instructions on disposal of all waste water from the sprayer.

 

 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV antifreeze through the system. This will keep internal parts lubricated, protect against 

corrosion and keep the unit from freezing. 

Note: RV antifreeze is non-toxic and biodegradable and generally safer for the environment than automotive 

antifreeze.

 

Before storing your sprayer for winter or long term storage, thoroughly clean and drain it as much as possible. Then pour enough pink RV antifreeze 

into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system, including the bypass. Make sure 

to operate the boom and handgun until you see pink fluid spraying from the nozzles. Leave any remaining antifreeze in the tank. Before your next 

usage, rinse the antifreeze from the sprayer with clean water. 

It is nearly impossible to drain all of the water from the sprayer and any trapped water can freeze in cold weather and damage parts of the sprayer. 

Pumping the antifreeze through the system will displace the water and help prevent this damage. 

 

Removing from storage: drain the antifreeze. Fill the tank with fresh water and run through the system. Dispose of antifreeze and flush water properly. 

1

MPH

2

MPH

3

MPH

4

MPH

5

MPH

10

.30

44

22

14.9

11.1

8.9

20

.42

63

31.5

20.9

15.7

12.6

30

.52

76

38

26

19.3

15.4

40

.60

90

45

30

22

17.8

1

MPH

2

MPH

3

MPH

4

MPH

5

MPH

10

.30

1.01

.5

.34

.254

.204

20

.42

1.4

.72

.48

.36

.29

30

.52

1.74

.87

.596

.44

.35

40

.60

2.06

1.00

.688

.50

.408

1

MPH

2

MPH

3

MPH

4

MPH

5

MPH

10

.30

.10

.05

.034

.025

.02

20

.42

.14

.072

.048

.036

.029

30

.52

.174

.087

.059

.044

.035

40

.60

.206

.10

.068

.05

.04

3

(Gray)

Tip

No.

(Color)

Pressure

(psi)

Capacity

(GPM)

Gallons Per 1000 Sq. Ft. - Based on Water

3

(Gray)

Tip

No.

(Color)

Pressure

(psi)

Capacity

(GPM)

Gallons Per Acre - Based on Water

Tip Chart for TKT-VP3, TF-VP3 & 30DT3.0 Tips

Tip

No.

(Color)

Pressure

(psi)

Capacity

(GPM)

Gallons Per Acre - Based on Water

3

(Gray)

Summary of Contents for 5301439

Page 1: ...s with an On Off shut off valve located at the inlet location of the tank towards the underside See Detail A You must make sure the valve is in the open position before using your sprayer Detail A OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industrie...

Page 2: ...our sprayer s carton LG 1500 304 Contents of Parts Bag 5278316 Tank Lid Lanyard 5058188 Tank Frame Pre Assembly 2 Nozzle Boom Assembly 5277774 2 Tires Wheels 5021092 Owner s Manual 15 20 Gallon Trailer Bracket Kit 5277727 ...

Page 3: ...he axle and 2 wheels from the carton Remove the 2 wheel spacers and 2 cotter pins from the parts bag Slide the axle through the hole in one side of the frame and through the corresponding hole on the other side of the frame You may need to maneuver squeeze the frame slightly while doing this to get the axle through both holes Center the axle about the frame as best as possible Slide a wheel spacer...

Page 4: ...o the tank Do not over tighten These clips are where the spray gun is secured to the tank while not in use NOTE The spray gun should already be attached to the 15 foot hose prior to assembly The Sprayer should now be ready for use Assembly Procedure LG 1500 304 Remove the 2 nozzle boom assembly from the carton Using 2 bolts and 2 whiz nuts bolt the boom to the upright boom mounting brackets There ...

Page 5: ...en disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch tha...

Page 6: ...me chemicals will damage the pump valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical manufacturer s instructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze thr...

Page 7: ...alve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adju...

Page 8: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Page 9: ...Page 9 Manifold Detail Exploded View Parts List LG 1500 304 5301439 Intake Detail ...

Page 10: ...ggested Minimum Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The criti cal factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift ...

Page 11: ... filter screen Start your pump and before it shuts off reach down and shut the valve to the Closed position lever is perpendicular to the flow of fluid then shut off your pump Unscrew the knurled nut from the shut off valve leaving the valve connected to the tank Swing swivel the intake assembly towards you Look in the nut you JUST unscrewed There is a screen washer there Remove the screen and cle...

Page 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: