background image

309884G

Manufactured by

ti6911a

Instructions – Parts List

Mustang 3100 Airless Paint Sprayer

– For portable spray application of architectural paints and coatings –

Model 246792

3000 psi (207 bar, 20.7 MPa) Maximum Working Pressure

IMPORTANT SAFETY INSTRUCTIONS

Read all warnings and instructions in this manual.
Save these instructions.

Table of Contents

Warnings

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Grounding and Electrical Requirements

4

. . . . . . . . . . . 

Pressure Relief Procedure

5

. . . . . . . . . . . . . . . . . . . . . . . 

Component Function and Identification

6

. . . . . . . . . . . . 

Setup

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Priming

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Tip Selection

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Spraying Techniques

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Shutdown and Cleaning

18

. . . . . . . . . . . . . . . . . . . . . . . . 

General Repair Instructions

21

. . . . . . . . . . . . . . . . . . . . . 

Basic Troubleshooting

22

. . . . . . . . . . . . . . . . . . . . . . . . . 

Advanced Troubleshooting

24

. . . . . . . . . . . . . . . . . . . . . . 

List of Kits

31

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Motor Diagnostics

32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Control Board Diagnostics

32

. . . . . . . . . . . . . . . . . . . . . . 

Pump Diagnostics

33

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Pump Repair

33

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Parts 34

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Technical Data

37

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

ASM Warranty 

38

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Parts

Summary of Contents for 246792

Page 1: ...n this manual Save these instructions Table of Contents Warnings 2 Grounding and Electrical Requirements 4 Pressure Relief Procedure 5 Component Function and Identification 6 Setup 8 Priming 9 Tip Selection 14 Spraying Techniques 16 Shutdown and Cleaning 18 General Repair Instructions 21 Basic Troubleshooting 22 Advanced Troubleshooting 24 List of Kits 31 Motor Diagnostics 32 Control Board Diagnos...

Page 2: ... arc D Sprayer generates sparks When flammable liquid is used in or near sprayer or for flushing or cleaning keep sprayer at least 20 ft 6 m away from explosive vapors D Keep work area free of debris including solvent rags and gasoline D Do not plug or unplug power cords or turn lights on or off when flammable fumes are present D Ground equipment and conductive objects in work area Read Grounding ...

Page 3: ...replace worn or damaged parts immediately with genuine ASM replacement parts only D Do not alter or modify equipment D Use equipment only for its intended purpose Call your ASM distributor for information D Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces D Do not kink or overbend hoses or use hoses to pull equipment D Keep children and animals away from wor...

Page 4: ...ance D Ground sprayer gun through connection to a properly grounded fluid hose and pump D Ground fluid supply container Follow local code D Ground solvent pails used when flushing Follow local code Use only conductive metal pails placed on a grounded surface such as concrete Do not place the pail on a non conductive surface such as paper or cardboard which interrupts the grounding continuity Fig 3...

Page 5: ...owest setting Hold metal part of gun firmly to a grounded metal pail Trigger gun to relieve pressure Fig 8 ti6912a 4 Engage trigger lock Fig 9 ti6763b D Leave Spray Prime Drain valve in PRIME DRAIN position until you are ready to spray again D If you suspect the spray tip is clogged or that pressure has not been fully relieved after following the above steps VERY SLOWLY loosen tip guard retaining ...

Page 6: ...C H F X D A W B M L J P K G E Mustang 3 Spray Gun Q R S T V U ti5453b ti6911a 6 309884 Component Identification and Function ...

Page 7: ...paint hose in SPRAY position pointing forward D Directs fluid to drain tube in PRIME DRAIN position pointing down D Automatically relieves system pressure in overpressure situations K Fluid inlet connection and inlet valve Where suction tube connects to pump and inlet valve L Inlet screen Prevents debris from entering pump M Paint hose Transports high pressure fluid from pump to spray gun P Airles...

Page 8: ...un 3 Connect other end of hose to sprayer NOTE If hose is already connected make sure connections are tight 4 Turn OFF power switch 5 Turn Pressure Control Knob all the way left counterclockwise to minimum pressure NOTE To select function align symbol on Pressure Control Knob label with arrow on sprayer Fig 10 Fig 10 ...

Page 9: ... 13 4 If spraying oil based materials submerge suction tube in mineral spirits or compatible oil based cleaning solution If spraying water based materials submerge suction tube in water Fig 14 Mineral Spirits WATER OR 5 Plug sprayer into grounded outlet 6 Point gun into waste pail Fig 15 WASTE ti6913a 7 Turn power switch ON Fig 16 8 Turn up pressure control knob until pump starts Fig 17 ti6906a 9 ...

Page 10: ...the pump s two check valves to malfunction If the pump does not prime after 30 seconds try to jar the check balls loose by tapping the inlet valve with a small wrench as the sprayer is on and running CAUTION Excessive shock will fracture or cause other damage to the pump Fig 21 Tap here ti6915a HINT To determine if the inlet valve ball is sticking unscrew inlet valve from pump and check it Inlet v...

Page 11: ... smaller from suction tube larger Fig 23 prime tube suction tube 3 Place prime tube in waste pail Fig 24 4 Place suction tube in bucket of mineral spirits Fig 25 Mineral Spirits 5 Plug sprayer into grounded outlet 6 Point gun into waste pail Fig 26 WASTE ti6913a 7 Turn power switch ON Fig 27 8 Turn up Pressure Control knob until pump starts Fig 28 ti6906a 9 Flush until mineral spirits flow out of ...

Page 12: ...igger and turn Spray Prime valve to SPRAY When paint comes out of gun release trigger Fig 32 WASTE SPRAY pull and hold trigger paint ti6914a NOTE Motor stopping indicates pump and hose are primed with paint 14 Attach drain tube to suction tube NOTE If pump does not prime after 30 seconds see Pump Check Valves page 10 ...

Page 13: ... and base assembly onto gun and tighten retaining nut by hand Fig 34 ti6772a NOTE Point the arrow shaped handle on the Uni tip forward to SPRAY and backward to UNCLOG obstructions Fig 35 UNCLOG arrow points backward SPRAY arrow points forward ti6774a ti6775a NOTE D Tip must be pushed all the way into base D Never pull gun trigger when arrow shaped handle is between SPRAY and UNCLOG positions ...

Page 14: ...o 10 in 203 to 254 mm fan width and a 0 013 in 0 33 mm hole size order Part No 59 413 Using the Right Tip for the Job Consider the coating and the surface to be sprayed Make sure you use the best tip hole size for that coating and the best fan width for that surface Tip Hole Size Tip hole size controls the flow rate the amount of paint that comes out of the gun HINTS D Generally use larger tip hol...

Page 15: ...ontain information about the hole size and about the fan width on the surface when the gun is held 12 in 30 5 cm from the surface being sprayed First digit when doubled approximate fan width Last two digits tip hole size in thousands of an inch 413 tip has a 0 013 in hole size 413 tip has 8 to 10 in fan width ...

Page 16: ...uld be atomized evenly distributed no gaps at edges Fig 36 Start at low pressure setting increase pressure a little at a time until paint is atomized Fig 36 A good spray pattern pressure too low gaps at edges D To prevent excessive tip wear spray at lowest pressure that atomizes paint D If maximum pressure of sprayer is not enough for good spray pattern tip is too large or too worn Getting Started...

Page 17: ...igger after starting stroke release trigger before end of stroke Gun must be moving when trigger is pulled and released Fig 39 Fig 39 pull release Aiming Gun D Aim tip of gun at edge of previous stroke to overlap each stroke by half Fig 40 Fig 40 aim here ...

Page 18: ... under pressure for the fluid filter system to be activated If the sprayer has no pressure it needs to be primed 1 With Power switch OFF lift suction tube and prime tube from paint pail and let them drain into paint for awhile Place suction tube in flushing fluid pail and place prime tube in waste pail Turn Spray Prime valve to PRIME to relieve fluid pressure into waste pail WASTE FLUSHING FLUID 9...

Page 19: ...m suction tube and place tube in waste bucket 6 Connect garden hose to suction tube with Zip Flush attachment Leave prime tube in waste pail 7 Turn Spray Prime Valve to SPRAY Align arrow on sprayer with bucket symbol on Pressure Control Knob 8 Open lever on Zip Flush attachment Turn on garden hose NOTE Step 9 is for returning paint in hose back to paint pail One 50 foot 15 meter hose holds approxi...

Page 20: ...hose in storage fluid bottle and prime tube in waste pail 2 Turn Spray Prime Valve to PRIME 3 Turn pressure control knob all the way left counterclockwise to minimum pressure 4 Turn power switch ON 5 Align arrow on sprayer to roller symbol on pressure control knob 6 When storage fluid runs out of prime tube 5 10 seconds turn power switch OFF 7 Turn Spray Prime Valve to SPRAY to keep storage fluid ...

Page 21: ...enclosure Replace if damaged Enclosures direct cooling air around the motor to prevent overheating They also reduce the risk of burns fire or explosion Read the following WARNING CAUTION Do not run sprayer dry for more than 30 seconds Doing so could damage pump packings Protect the internal drive parts of this sprayer from water Openings in the enclosures allow for air cooling of the mechanical pa...

Page 22: ... replace check valves See Pump Service on page 33 Do not store in water Suction tube is leaking Tighten suction tube connection K Inspect for other cracks or vacuum leaks Spray gun stopped spraying Spray tip is plugged Unplug spray tip Pump cycles but does not b ild Pump is not primed Prime pump p y build up pressure Inlet screen is clogged or suction tube is not immersed Clean debris off inlet sc...

Page 23: ...mage can occur if cause is not corrected Sprayer was operated at high pressure with very small tip which causes frequent motor starts and excessive heat build up Decrease pressure setting or increase tip size Building circuit breaker opens after sprayer operates for 5 to 10 minutes OR Too many appliances are plugged in on same circuit Free up circuit unplug things or use a less busy circuit OR Bui...

Page 24: ...ng Motor Kit 245063 Yoke is broken because pump is locked up by dried paint or worn packings Repair as necessary or replace using Gear Yoke Repair Kit 245063 Basic Electrical Problems Motor is overheated Allow to cool for 30 minutes Retry Electrical outlet is damaged Reset building circuit breaker or replace building fuse Try another outlet Check electric supply with volt meter Meter must read 85 ...

Page 25: ...switch B and unplug in line connection of white electrical cord wire Plug in electrical cord and test voltage between black and white electrical cord wires Meter must read 85 to130 Vac Replace electrical cord if no voltage Sprayer power switch B is damaged Unplug sprayer electrical cord Disconnect black control board wire at Power switch B and unplug in line connection of white electrical cord wir...

Page 26: ...ard if damaged using Control Board Kit 243228 Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on NOTE Remove right enclosure mounting screws and pull right enclosure away from drive housing Take care t t ll th l d f Sprayer electrical cord is damaged Unplug sprayer electrical cord Disconnect black electrical cord wire at Power switch B and unplug ...

Page 27: ...leshooting page 22 Pump valves are worn or obstructed by debris Check for worn pump valves as follows Prime sprayer with paint Trigger spray gun momentarily When spray gun trigger is released pump should cycle momentarily and stop If pump continues to cycle pump valves may be worn or obstructed See Pump Service on page 33 Spray Prime Drain valve is leaking Check Spray Prime Drain valve for debris ...

Page 28: ... on page 32 If shorts are evident replace motor using Motor Kit 245063 Control board is damaged CAUTION Do not perform control board diagnostics until you have determined that the armature is good A bad motor armature can burn out a good control board See Control Board Diagnostics on page 32 and if damaged replace control board using Control Board Kit 243228 General Problem Output is Low or Fluctu...

Page 29: ...ected with tab to the right Control board is damaged CAUTION Do not perform control board diagnostics until you have determined that the armature is good A bad motor armature can burn out a good control board See Control Board Diagnostics on page 32 If damaged replace control board using Control Board Kit 243228 Pressure control switch is damaged or worn out Replace pressure control switch using P...

Page 30: ...ntrol switch is worn Replace pressure control switch using Pressure Control Switch Kit 244267 through drain tube Water or paint entered pressure control switch or shorted control board Clean out and or dry out and retry Replace if necessary using Pressure Control Switch Kit 244267 Control board has failed See Control Board Diagnostics on page 32 and replace control board if damaged using Control B...

Page 31: ... 8 bronze bearing motor casting includes fan shroud brace Series C 243231 Fan Shroud Brace Series A and B 287770 Fan Series C 243228 Control Board 245062 3 8 Shaft Gear Yoke Guides bronze bearing equipped cover and motor castings 245578 Inlet Strainer for inlet of suction tube 245053 Pump Replacement complete pump Does not include Pressure Control Switch 244267 Re use pressure control switch from ...

Page 32: ...1 Connect red and black motor leads together with test lead Turn motor fan by hand at about two revolutions per second 2 If there is uneven resistance or no resistance replace motor using Motor Kit 245063 Control Board Diagnostics Check for a damaged control board or pressure control switch as follows 1 Unplug electrical cord and relieve pressure 2 Remove the four cover screws and front cover 3 Re...

Page 33: ...ional dam age to the drive train could occur Use pump repair kit 245569 Pump Service CAUTION When repairing or cleaning the pump never submerge the pump in water or allow fluid to enter the pressure control If the sprayer continues to cycle motor and pump run when the spray gun trigger is released or if perfor mance is poor even with new spray tips and clean fil ters the pump inlet or outlet valve...

Page 34: ...s A and B 118899 Series C 67 195433 SUPPORT right Series A 1 15D923 SUPPORT right Series B C 1 68 195434 SUPPORT left Series A 1 15D924 SUPPORT left Series B C 1 69 195436 FRAME cart 1 70 195435 HANDLE cart 1 71 15D650 HOSE RACK 1 Ref No Part No Description Qty 72 115097 SCREW curved head 2 73 115480 KNOB t handle 2 74 197285 AXLE 1 75 195367 SPACER 2 76 115095 WHEEL 9 2 77 112612 CAP 2 79 105521 ...

Page 35: ...and B 63 66 61 62 79 67 68 79 77 76 75 74 80 72 65 72 47 51 73 113 70 1 65 13 54 58 46 71 86 87 88 89 52 69 36 52 81 43 44 45 19 18 52 84 102 48 125 125 25 17 94 88 2 127 95 96 149 126 1 Apply light coat of lithium based grease 1 40 151 ti5451b 85 20 26 ...

Page 36: ...s C 63 62 79 67 68 79 77 76 75 74 80 72 65 72 73 113 70 1 65 13 71 86 85 20 87 88 89 69 36 52 81 43 44 45 19 18 84 102 25 17 26 94 88 2 127 95 96 149 1 Apply light coat of lithium based grease 1 40 66 47 51 54 58 46 52 52 48 125 125 123 ti6917a 151 ...

Page 37: ...se thread Fluid outlet fitting 1 4 npsm external thread Inlet screen on suction tube 35 mesh 450 micron Wetted parts pumps and hose Stainless steel brass leather ultra high molecular weight polyethylene UHMWPE carbide nylon aluminum PVC polypropylene fluroelastomer Generator requirement 1500 Watt minimum Electric power requirement 120 Vac 60 Hz 1 phase 15 A Storage temperature range 30_ to 160_F 3...

Page 38: ... EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ASM s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other i...

Reviews: