10.2 Start-up
CAUTION!
High viscosity
Damage to property
If high-viscosity media are used, the filter
controller should not be switched on until the
filter reaches its normal service temperature
(refer to the Instruction Manual for the E900 filter
controller).
Switch on the filter controller (refer to the Instruction
Manual for the E900 filter controller).
Slowly open the inlet.
Vent the automatic filter with the vent screw (1).
Fig. 4:
Venting the filter
Start a manual cleaning cycle (refer to the
Instruction Manual for the E900 filter controller).
Initial differential pressure
The initial differential pressure varies according to
the application.
General guide:
Installation on discharge side:
p
≤
0.1 bar
11
Normal operation
DANGER!
Danger due to high pressure in the automatic filter!
Risk of injury to persons or damage to property
Do not allow concentrate to spatter into the
atmosphere!
Always dispose of the flush volume /
concentrate in a manner which does
not pollute the environment or process
it professionally!
Consult the responsible authorities
before deciding upon the most suitable
disposal method.
The following must be monitored daily during
normal operation:
Differential pressure
Controller function
12
Shutting down the automatic filter
12.1 Temporary shut-down
Switch off the main switch on the filter controller
(refer to the Instruction Manual for the E900 filter
controller).
12.2 Prolonged shut-down (>48 h)
Start a manual cleaning cycle (refer to the
Instruction Manual for the E900 filter controller).
Make sure the inlet and outlet are closed.
Switch off the main switch on the filter controller
(refer to the Instruction Manual for the E900 filter
controller).
Remove the filter insert (refer to section 14.4).
Clean the filter insert (refer to section 14.5.1).
Reinstall the filter insert.
Fill the automatic filter completely with liquid.
12.3 Emergency shut-down
Switch off the main switch on the filter controller
(refer to the Instruction Manual for the E900 filter
controller).
The power supply is interrupted.