Translation of the original instructions with installation instructions R5- Filtration Group GmbH,, 24.05.2019, Mat. No. 70580785, Revision 04
9
Installation instructions
DANGER!
Danger of electric shock!
Risk of serious or fatal injury in
case of contact with electrical
components.
All electrical installation work must
be carried out by a suitably qualified
electrician.
WARNING!
If the system is installed by unauthorised persons
Risk of injury
All warranty claims are rendered invalid
The plant must be installed by a suitably trained
person!
Provide stress relief for all pipe connections.
Make sure the filter does not run dry via the pipes
when the plant is not operating.
Provide a bypass pipe if necessary.
Connect the flush pipes to flush valves.
Make sure the flush pipe is able to run dry. (only
dirt side)
Connect the electrical power supply according to
the circuit diagram.
Connect an electrically isolated contact to the visual
or audible alarm device.
Protect the electrical lead with a 3 x 4 A fuse.
10
Start-up
DANGER!
This automatic filter is not allowed to be put into
operation until it has been established that the machine /
plant in which it is to be installed complies with the
classifications of the acceptance authority.
DANGER!
Danger due to high pressure in the automatic filter!
Risk of injury to persons or damage to property
Do not allow the flush volume / concentrate to
spatter into the atmosphere!
Make sure that:
All foreign particles are removed from the
automatic filter.
All pipe connections are tightened securely.
All screws are tightened.
10.1 Functional test
To test the pressure transmitter / differential pressure
switch (optional)
Refer to the enclosed
manufacturer’s
documentation.
To test the functioning of the flush valve (pneumatic
actuator)
Make sure the flush lines are connected
Supply compressed air to the pilot valve.
Press the hand release for the pilot valve.
The flush valves open.
Set the hand release for the pilot valve to the OFF
position.
The flush valves close.
Refer to the enclosed manufacturer’s
documentation.
To test the functioning of the electric actuators
Refer to the Instruction Manual for the E900 filter
controller.