Read  these  instructions  carefully  and  completely  before  attempting  to  unpack,  install  or  service  the 
bursting  disc and holder. 

 

Do not vent a bursting  disc assembly  to an area where it would endanger  personnel. 

 

Install  the  bursting  disc  assembly  in  such  a  way  that equipment  in the  area  will  not  prevent bursting  disc 
from opening  or be damaged  by system  discharge. 

 

A  baffle  plate  on  the  outlet  end  of  vent  piping  does  NOT  necessarily  prevent  potentially  dangerous 
discharge. 

 

Piping should  be braced to absorb shock when the bursting disc ruptures. 

 

Install the enclosed  DANGER  sign in a conspicuous location  near the zone of potential  danger. 

 

RD520 Axius and RD320 are not  suitable  for  liquid  systems  in  a 1”  size (DN25)  at  burst pressures  less  than 
20 psig (1.38 barg) and an inlet piping length greater than 10 inches (25 cm). 

 

RD520 Axius and RD320 are not suitable for liquid systems in a ¾” size (DN20) at burst pressures less than 
30 psig (2.07 barg) and an inlet piping greater than 8 inches (20 cm). 

 

RD500 Atlas and RD 300 are not suitable  for liquid systems in sizes 14” (DN350) and larger. 

 

Spiral  wound  gaskets  may not be  suitable  for size 1” (DN25). Spiral wound gaskets may not be suitable for 
all flange ratings for sizes 2” (DN50) to 4” (DN100). Consult factory. 

 

If the bursting disc features a fluoropolymer liner, do not remove this component. 

NOTE: Bursting disc specifications and year of manufacture can be found on the bursting disc tag. 

Table 1 - Disc/Holder model compatibility 

Disc Model 

Holder Model 

SRX 

SRL / SRLO 

XL / XLO 

ATLAS / ATLAS-LO 

SRX 

 

 

 

 

SRL 

 

  

 

1

 

 

RD520 Axius 

 

 

2

 

 

 

RD320 

 

 

2

 

 

 

RD500 ATLAS 

 

 

 

 

RD300 

 

 

 

 

AGT 

 

 

 

 

 

(1)

 

1.5” SRL disc not compatible with 1.5” XL/XLO holder 

(2)

 

1.5” RD520 Axius and RD320 disc not compatible with 1.5” SRL/SRLO holder 

 

 

 

Summary of Contents for RD300 Holder

Page 1: ...rotection Overpressure Protection Pressure Activation INSTALLATION AND MAINTENANCE INSTRUCTIONS Reverse Acting Bursting Disc Assemblies SRX SRL RD520 Axius RD320 RD500 Atlas RD300 Holder PRESSURE RELI...

Page 2: ...CIFIC PURPOSE Refer to www fike com terms conditions for Fike s full TERMS AND CONDITIONS OF SALE TERMS OF USE Do not alter modify copy or otherwise misappropriate any Fike product whether in whole or...

Page 3: ...Doc P N 8 8128 00 3 Rev 3 July 2020 PAGE 1 REVISION HISTORY ORIGINAL RELEASE DATE June 2017 REVISION DESCRIPTION OF CHANGE REVISION DATE...

Page 4: ...ly 2020 TABLE OF CONTENTS Section Page No 1 WARNING 3 2 INSPECTION PREPARATION 4 2 1 New Bursting Discs 4 2 2 New Holder 4 2 3 Existing Holder 5 3 ASSEMBLY 6 4 INSTALLATION 9 4 1 Connecting grounding...

Page 5: ...sures less than 20 psig 1 38 barg and an inlet piping length greater than 10 inches 25 cm RD520 Axius and RD320 are not suitable for liquid systems in a size DN20 at burst pressures less than 30 psig...

Page 6: ...isc See Figure 1 3 If foreign material is present carefully clean the bursting disc with a solvent that is compatible with your media Figure 1 Check for damage NOTE Handle bursting disc holders with c...

Page 7: ...s left from the media 5 Check to make sure the gasket faces of the assembly are flat by placing a straight edge across the face If faces are not flat holder is not suitable for use See Figure 3 Figure...

Page 8: ...not required for proper function of the bursting disc assembly Do not install an o ring unless the holder is designed to accept these components by Fike 3 Place bursting disc into holder component wit...

Page 9: ...figure 7 Fragmentation or leaking can occur if this feature is not aligned properly 6 Rotate component with male seat to align side clip holes 7 If holder configuration is insert install side clips a...

Page 10: ...ue the cap screws to the values shown on the tag of the holder using crisscross pattern in 20 increments until the torque specified on the tag is achieved on all cap screws The torque values of the fl...

Page 11: ...spool piece if under a pressure relief valve Refer to Fike Technical Bulletin TB8105 for code requirements WARNING Double check the orientation of the bursting disc Verify flow arrows on the holder a...

Page 12: ...FACES ON ALL SIDES 8 Experience has shown that in some installation conditions it may be necessary to re torque the flange bolting after the system has operated through normal pressure and temperatur...

Page 13: ...Doc P N 8 8128 00 3 Rev 3 July 2020 PAGE 11 Figure 9 connecting grounding grounding holder grounding disc...

Page 14: ...0 Connect the braided SST grounding strip or grounding wire not included to an appropriate ground and the explosion panel Pay extra attention to the grounding connections Install serrated lock washers...

Page 15: ...a nut factor K 0 2 Adjustments to the torque should be considered if the installation utilizes bolting lubrication with a nut factor other than K 0 2 The following expression may be used for correctio...

Page 16: ...1 Mandatory Appendix II guidelines Torque values in Appendix A are based on a nut factor K 0 2 Adjustments to the torque should be considered if the installation utilizes bolting lubrication with a nu...

Page 17: ...Notes...

Page 18: ...NTACT US Fike Europe Toekomstlaan 52 2200 Herentals Belgi Tel 32 14 210031 www Fike com For a list of contact information for Fike offices around the world visit the Global Locations section of Fike c...

Reviews: