SUPPLEMENTARY OPERATING MANUAL
2
2
-
8
02-11-05
CDP-01
Figure Sheet 1-811-B
Start-up / Mandrel Drive Polarity
Press the Servo Center key. Verify that the mandrel
moves to the center of the stroke.
If the mandrel moves to either end, press the Manual
key and change the Servo Center polarity.
Reference:
CDP-01 Reference Manual, section “Servo
Center Polarity”.
If the mandrel oscillates, press the Manual key and
change the Servo Center gain.
Reference:
CDP-01 Reference Manual, section “Servo
Center Gain”.
Place a web in the sensor, positioned for normal
guiding.
Connect the parallel cable and select ‘Automatic with
Edge R Sensor’ via external control.
Move the web momentarily back and forth in the sensor
field of view. If the mandrel stops moving when the web
is not moving, repeat this portion of the procedure for
Edge L and Edge Center sensor modes with the web
placed in the corresponding sensor(s) field of view,
then skip the rest of this portion of the procedure.
If the mandrel moves to either end of the stroke, select
‘Manual’ via external control.
Verify that the correct sensor mode is selected:
Edge Left
Edge Right
or
Edge Center
Change the guide polarity.
Reference:
CDP-01 Reference Manual, section
“Changing The Guide Direction”.
Repeat the portion of this procedure beginning with the
parallel cable connection.